Objectives: Failure of extubation of patients on mechanical ventilation is one of the common problems in the ICU. Aim of work: To evaluate the validity of lung ultrasound score in prediction of weaning outcomes and post-extubation distress.
Methods: A prospective observational study of 50 patients planned for extubation who passed a spontaneous breathing trial, lung ultrasound score and serum level of NT-PRO BNP were done to all patients at end of spontaneous breathing trial, and all patients were followed after extubation and monitored for oxygenation, re-intubation rate, ICU stay, and ICU mortality.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE
Enrollment
50
Lung ultrasound score was done at the end of SBT using curved array ultrasound probe 2-5 MHz, Siemens X300, Korea
Cairo University Hospitals
Cairo, Egypt
Extubation success
number of participants that do not need for respiratory support neither NIV nor intubation for one week during ICU stay
Time frame: 48 hours