A prospective observational study guided by the guidelines of Strengthening The Reporting Of Observational Study in Epidemiology (STROBE) in 2014, that will be conducted to evaluate implant stability using three devices; Osstell®, Peiotest® and AnyCheck® and comparing the results.
In this study, 40 dental implants will be installed in osteotomy sites for patients with single or multiple missing tooth or teeth based on radiographic findings (CBCT). The primary stability will be measured immediately after implant installation using three devices : 1. Osstell : based on resonance frequency analysis (RFA). 2. Periotest: based on damping effect. 3. AnyCheck: based on tapping motion. Secondary stability will be measured after 12 weeks using the same devices mentioned above.
Study Type
OBSERVATIONAL
Enrollment
16
1. Osstell®: is a device that measure implant stability and based on resonance frequency analysis (RFA). Due to stiffness in the interface between the implant surface and the bone smart peg will vibrates accordingly. the more dense bone the higher stability, the higher frequency and higher Implant Stability Quotient (ISQ) value which is from 1-100. 2. Periotest®: is a device used to assess osseointegration of dental implants, so it measure implant stability . it is based on damping effect of implant. Showing the measurement digitally on a scale from -8 (low mobility) to 50 (high mobility) PTV units. 3. AnyCheck®: this is an implant stability meter that measures the stiffness of alveolar bone-implant interface through a tapping motion. Showing the measurement on a scale from 30 (low stability) to 85 (high stability).
College of Dentistry, University of Baghdad
Baghdad, Medical City, Iraq
Implant stability measured by Osstell®.
Implant stability will be measured by: Osstell® (RFA) that is measured by Implant Stability Quotient (ISQ) Value.
Time frame: Changes in implant stability from baseline value measured immediately after implant installation (primary stability) and after 12 weeks (secondary stability).
Implant stability measured by Periotest®.
Implant stability will be measured by: Periotest® (damping effect) that is measured by Periotest Value (PTV).
Time frame: Changes in implant stability from baseline value measured immediately after implant installation (primary stability) and after 12 weeks (secondary stability).
Implant stability measured by AnyCheck®.
Implant stability will be measured by: AnyCheck® (tapping-motion) that is measured by Initial Stability Test (IST) Value.
Time frame: Changes in implant stability from baseline value measured immediately after implant installation (primary stability) and after 12 weeks (secondary stability).
Correlation between values obtained by the devices
Correlation between values obtained by: 1. Osstell® (RFA): measured by Implant Stability Quotient (ISQ) Value. 2. Periotest® (damping effect): measured by Periotest Value (PTV). 3. AnyCheck® (tapping-motion): measured by Initial Stability Test (IST) Value.
Time frame: Changes in implant stability from baseline value measured immediately after implant installation (primary stability) and after 12 weeks (secondary stability).