Implant devices are important tools - their use is essential across a number of orthopaedic indications, including hip conditions, trauma and limb deformity. Given the vital role fixation devices play in maintaining alignment, promoting healthy bone healing and preventing joint degeneration, it is essential to understand the expected lifetime outcomes of these implants, and evaluate their safety and efficacy. Prospective implant efficacy and safety registries are needed to support this endeavour, especially considering new regulatory requirements from the European Union Medical Devices Regulation (EU MDR) in relation to post-market clinical follow-up (PMCF).
STUDY PROCEDURES Screening Patients will be screened against basic inclusion/exclusion criteria to see if patients may be appropriate for study participation according to any standard of care assessments available, and where appropriate with the site's REB/IRB screening procedures and local regulatory requirements. If a patient is deemed eligible, data outlined throughout this protocol will be collected, de-identified and entered into a Research Electronic Database Capture (REDCap) system managed at BCCH. Enrollment Patients will be assigned a sequential, unique study number (subject ID) and de-identified data will be entered in the study database. The center number is designated by the BCCH team for each individual investigational site. The patient number will be in sequential order by the patient screening date starting with 001. Once a patient has been assigned a subject ID, the number will not be reused. Pre-Operative Procedures Once a patient is identified as eligible for an Implant Safety and Efficacy device report, it will be determined whether that patient is already enrolled in one of the existing condition-specific registries. Should participants be enrolled in a condition-specific registry, demographic data, medical history, preoperative clinical data, including any pre-existing infections at or near the operative site, and data on pre-operative radiographs for the relevant underlying diagnosis will have already been prospectively collected under registry procedures. If a patient has not been previously enrolled in a condition-specific registry, the patient will be offered enrollment in both the condition registry and for the purposes of the Implant Safety and Efficacy device report. Demographic data, medical history, preoperative clinical data and data on pre-operative radiographs for the relevant underlying diagnosis will then be collected retrospectively from the medical record. Required Data Collection: Operative details in the source documentation will be collected that provide specific information from the subject's surgery such as surgical approach, complications, and unique device identification (UDI) numbers for the implanted device. The following data will be collected and entered into the registry: * Operative data, specific to the technique related to the relevant OrthoPediatrics system/device * Assessments of any device-related adverse events * Assessment for other adverse events * When possible, the UDI number for the device(s) implanted, or information on the device implanted Follow-up Procedures Data collected during routine standard of care follow-up visits will be collected as part of this study. The following data will be collected: * Radiographs obtained during study clinical evaluations to determine bony union, as well as healing or complications * Device-related adverse events * Unanticipated device-related serious adverse device effects * Information on implant removals not related to an adverse event; degree of bony union just prior to implant removal Unscheduled Visits \[if or when needed\] The condition-specific registries are designed to capture every visit that occurs, whether scheduled or unscheduled. An unscheduled visit may occur when an adverse event occurs, or when a patient returns outside of the planned interval window. If an unscheduled visit occurs, the following assessments are to be done: * Assessment of any adverse events related to the device * Survivorship of the device
Study Type
OBSERVATIONAL
Enrollment
4,000
Patient receives a pediatric orthopaedic implant as a part of standard clinical care.
BC Children's Hospital
Vancouver, British Columbia, Canada
RECRUITINGDevice related adverse events
Determine the frequency and severity of device-related adverse events at device-specific end points. All adverse events will be recorded and followed during the study. The frequency and severity of device related adverse events will be analyzed to ensure the device risk profile has not changed.
Time frame: 2 years post implant insertion
Implant survival
Determine the implant survival rate at post-operative end-point: (lack of revision)
Time frame: 2 years post implant insertion
Implant efficacy
Efficacy will be assessed by post-operative clinical and radiographic evaluations at each follow-up end-point to assess bone fixation and/or deformity correction.
Time frame: 2 years post implant insertion
Numeric pain rating scale (NPRS)
The numeric pain rating scale (NPRS) is a subjective, 11-point numerical scale in which respondents self-report their pain on a scale of 0 (no pain at all) to 10 (worst pain imaginable).
Time frame: 2 years post implant insertion
LIMB-Q Kids
LIMB-Q Kids is a new patient reported outcome measure (PROM) for children with lower limb deformities.
Time frame: 2 years post implant insertion
PROMIS
The Patient Reported Outcomes Measurement Information System (PROMIS) measures are self-reported and parent-reported. It includes over 300 measures of global, physical, mental, and social health for adults and children in the general population and those living with a chronic condition. Specifically, the PROMIS Global Health will be administered to all patients while the PROMIS Physical Function - Mobility short form will be administered to those with an implant used in a lower extremity and the PROMIS Physical Function - Upper Extremity short form will be administered to those with an implant used in an upper extremity.
Time frame: 2 years post implant insertion