The device which is the subject of this investigation is a robotic assistance module for the driving of a semi-autonomous electric wheelchair (FRE). It's intended to accessorize the FRE to improve the safety conditions during the driving of a FRE, making it possible to decrease the rate of accident in wheelchair on the one hand, increase the confidence of driving on the other hand, and facilitate the access to the FRE of people not being able to aspire to it without the use of a device of safety of this type.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
PREVENTION
Masking
NONE
Enrollment
1
use of anti-collision sensors on the electric wheelchair during 3 weeks
Use of an electric wheelchair without sensors for 3 weeks before using anti-collision sensors then during 3 weeks after using the anti-collision sensors.
Pôle Saint-Hélier
Rennes, Brittany Region, France
CCAS Saint-Etienne
Saint-Etienne, France
USLD Saint Etienne
Saint-Etienne, France
Evaluate benefits of using a FRE equipped with the assistance module on the confidence in driving electric wheelchair for elderly people in EHPAD
Evaluation by using the under score of confidence of Wheelchair Skill Test questionnaire (WST-Q-T 5.1) during the period of use of the module and at the end. The score goes from 0 to 56 (56 is the higher level of confidence).
Time frame: Day 42
Driving habilities
Benefits of the sensors on ability and performance of tasks performed with the electric wheelchair by Wheelchair Skill Test questionnaire (WST-Q-T 5.1). The score will go from 0 to 56 for each scale (performance and frequency), a high score will represent a good driving performance
Time frame: Day 42 and Day 63
Distance traveled measured by sensors on the FRE
The distance will be measured in meters with a lap counter type.
Time frame: Day 21, Day 42 and Day 63
Mesure of mental load related to wheelchair mobility
Mental load will be measured by the NASA-Task Load Index. It is in the form of six scales where the participant must assign a score between zero and one hundred to each of them, score indicating a growing level of intensity. Three dimensions relate to the demands imposed on the subject (mental, physical and temporal demands) and three to the interaction of a subject with the task (effort, frustration and performance).
Time frame: Day 21, Day 42 and Day 63
Ease of Use Questionnaire
Satisfaction of using FRE by users will be mesured by the Ease of Use Questionnaire. He is composed of 27 questions, each question is valued between 0 to 7. a high score will represent a high satisfaction.
Time frame: Day 42
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Acceptability of anti-collision sensors by users
A acceptability questionnaire based on the Unified Theory of Acceptance and Use of Technology (UTAUT) will be completed at day 42, with semi-directive interview