Investigator compared three techniques of Central venous cannulation (CVC) insertion, Anatomical Landmark, Pre-location Ultrasound and the Real Ultrasound techniques, in cardiac surgical patients.
Central venous cannulation (CVC) is the cannulation of a large central vein in neck (internal jugular vein), chest (subclavian or axillary) or groin (femoral vein). It is a standard clinical method performed for the monitoring of central venous pressure, temporary haemodialysis, drug administration (drugs irritating peripheral veins, chemotherapy, concentrated vasoactive drugs ) rapid infusion of fluids, inadequate peripheral intravenous access and sampling site for repeated blood sampling. There are different techniques for Central venous cannulation which include anatomical landmark and ultrasound guided (USG) technique. Previous studies have shown that the successful IJV cannulation using anatomical landmark technique was 85% as compared to ultrasound guided IJV cannulation which was 95%.The median catheterisation time of internal jugular vein via ultrasound guided (USG) is shorter than anatomical landmark technique. There has been little evidence regarding the use of ultrasound guidance for internal jugular vein cannulation at a tertiary care hospital in our population. Furthermore with widespread availability of ultrasound, Internal Jugular vein can be successfully cannulated with decreasing number of attempts, less time consumption and decrease in the incidence of complications.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
Enrollment
201
anatomical landmarks (sternocleidomastoid muscles, sternal notch, cricoid cartilage, carotid artery and clavicle) will be palpated. A 3cc syringe with 21 gauge needle (locator) will be used first to locate IJV at the apex of the triangle formed by the two heads of the sternocleidomastoid muscle. After successful location, an introducer needle of 18 gauge, attached with a 5 ml syringe, will be inserted at the same point. The introducer needle will be directed towards the ipsilateral nipple at an angle of 20-30° with the skin
In Group Ultrasound-guided pre location technique, venipuncture site will be determined using ultrasound probe which will be then removed and locator needle of 21 gauge will be used first to confirm IJV location. The cannulation or venipuncture will be performed at the marked point of locator needle by the use of 18 gauge introducer needle.
Aga Khan University hospital
Karachi, Sindh, Pakistan
Success Rate
Success rate will be measured according to the number of attempts. The cannulation of right Internal Jugular Vein within the first three attempts.
Time frame: Day 1
Time duration for each technique
Measurment of time in minutes
Time frame: Day 1
Incidence of Complications
Look for carotid puncture, haematoma formation , pneumothorax
Time frame: Day 1
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
In Group Ultrasound-guided real-time technique, cannulation or venipuncture will be performed under real-time imaging using 18 gauge needle i-e ultrasound will be used for prelocation and puncturing of IJV and locator needle will not be used