We are planning to measure hemodynamic parameters (Heart Rate, Mean Arterial Pressure, Stroke Volume Index, Stroke Volume Variation, and Pulse Pressure Variation) and ventilatory parameters at four times (T1, T2,T3, and T4) during spinal operation at prone position. First measurement (T1, First baseline) will be performed in the prone position after performing tracheal intubation and confirming hemodynamic stability (defined as mean arterial pressure \<10% for 3 minutes). After the T1 measurement, additional 5 cmH2O PEEP (Positive end-expiratory pressure) will be applied for 30 seconds which will be called as "short term low PEEP challenge (SLPC)". At the end of the SLPC and prior to PEEP lowering, T2 measurement will be performed and recorded. After the T2 measurement, PEEP will be decreased to the initial value (5 cmH2O) and three minutes later, a second baseline (T3) measurement will be performed. Thereafter, 500 ml isotonic saline will be loaded in 10 minutes. T4 measurement will be performed again three minutes after volume loading. All of the measurements will be completed before surgery start and surgical stimulus. Patients exhibiting an increase in stroke volume index more than 15% after fluid loading (between T3 and T4) will be classified as volume responders. Absolute pulse pressure variation change due to SLPC, Absolute Stroke volume variation change due to SLPC, stroke volume index percentage change due to SLPC, and stroke volume index percentage change after fluid loading will be calculated and compared. Our aim is to observe if short term low PEEP challenge has the ability to predict fluid responsiveness better than pulse pressure variation and stroke volume variation for patients operated in prone position.
Study Type
OBSERVATIONAL
Enrollment
53
Istanbul University
Istanbul, Turkey (Türkiye)
Verification of stroke volume index percentage change after SLPC
Stroke volume index percentage change after SLPC means " \[(SVIT2 - SVIT1) / SVIT1\] x 100".
Time frame: Up to 30 minutes
Verification of stroke volume index percentage change after fluid loading
Stroke volume variation and pulse pressure variation values will be measured at second baseline (T3) and after fluid loading (T4). Fluid responsive patients means " stroke volume index increase after fluid loading ≥ 15%". In another explanation; \[(SVIT4- SVIT3)/ SVI (T3)\]x100 ≥ 15% means fluid responsive patients.
Time frame: Up to 30 minutes
Ability of fluid responsiveness prediction with SVV, PPV, and Stroke volume index percentage change after SLPC
Predictive ability of SVI changes after SLPC and fluid loading will be compared by statistical analysis (ROC curve)
Time frame: Up to 30 minutes
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.