Background: Non-invasive ventilation (NIV) reduces respiratory load and demands on peripheral muscles. Methods: This study aims to evaluate the acute effects of bi-level NIV on peripheral muscle function during isokinetic exercise and aerobic performance in chronic obstructive pulmonary disease (COPD) patients. This is a pilot crossover study performed with a non-probabilistic sample of 14 moderate to very severe COPD patients. Procedures carried out in two days. Dyspnea, quality of life, lung function, respiratory muscle strength, functional capacity (6-minute walk test - 6MWT), and isokinetic assessment of the quadriceps were assessed. Blood samples (lactate, lactate dehydrogenase, and creatine kinase concentration) were also collected. Right after, NIV was performed for 30 minutes (bi-level or placebo, according to randomization) followed by new blood sample collection, 6MWT, and isokinetic dynamometer tests. Before and after evaluations, the subjective perception of dyspnea and fatigue in the lower limbs was quantified. After a wash-out period of seven days, participants returned, and all assessments were performed again.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
14
For the NIV intervention, two levels of positive airway pressure (bi-level) were used: the positive inspiratory airway pressure (IPAP) was fixed at 6 cmH2O (centimeters of water), which could be gradually increased up to 14 cmH2O (2 cmH2O every minute), depending on the patient's comfort. and gradually increased to 14 cmH2O (2 cmH2O every minute), While the expiratory airway pressure (EPAP) was set at 3 cmH2O, it could be gradually increased up to 7 cmH2O (1 cmH2O every minute), depending on the patient's comfort.while expiratory airway pressure (EPAP) was fixed at 3 cmH2O and gradually increased to 7 cmH2O (1 cmH2O every minute).
The same pressure chosen by the subject during adaptation was used in the placebo intervention; however, a T tube was connected between the equipment and the circuit, creating a leak and leaving the circuit open. The tube characteristics were: 22 x 18 x 22 mm nebulizer T-connector.
Federal University of Rio Grande do Norte
Natal, Rio Grande do Norte, Brazil
Lung function
Lung function was assessed using a spirometer (Koko Digidoser, Longmont, USA), according to the American Thoracic Society/European Throracic Society recommendations14. At least three tests were performed, with a variation of less than 5%, and the highest value obtained was compared with predicted values for the Brazilian population.
Time frame: change from baseline and 30 minutes after intervention
Respiratory muscle strength
Respiratory muscle strength was assessed using a digital manometer (MVD 300 - Brazil). Maximum inspiratory and expiratory pressures were performed from residual volume and total lung capacity, respectively, and values were compared with previously reference values for the Brazilian population
Time frame: change from baseline and 30 minutes after intervention
Functional capacity
The 6-minute walk test (6MWT) was performed in a flat 30-m corridor, according to the ATS recommendations17. Subjects were instructed to keep walking for six minutes, and standardized verbal incentives were given each minute. The perception of dyspnea (using the 10-point Borg scale) were assessed at rest, at the end of the 6MWT, and two minutes after the test. In this test, the walked distance (in meters) was considered for analysis.
Time frame: change from baseline and 30 minutes after intervention
COPD Assessement Test
The Portuguese version of the COPD Assessment Test (CAT) questionnaire was used to assess the quality of life. Subjects were instructed to choose only one option in each item of the questionnaire (cough, phlegm, chest tightness, breathlessness, limited activities, confidence leaving home, sleeplessness, and energy). Item scores range from 0 to 5 points resulting in a total score ranging from 0 to 40 points. The clinical impact of COPD was assessed according to the following stratification: mild (6-10), moderate (11-20), severe (21-30), and very severe (31-40)20.
Time frame: change from baseline and 30 minutes after intervention
Disease severity
COPD severity was assessed using the BODE index (body mass index \[B\], degree of airway obstruction \[O\], dyspnea \[D\], and exercise capacity \[E\]). For each variable, the following scores were assigned: body mass index (BMI), from 0 to 1 point; degree of airflow obstruction (FEV1% predicted), from 0 to 3 points; dyspnea (MRC scale), from 0 to 3 points; exercise capacity (walked distance in the 6MWT), from 0 to 3 points. The final score of the index ranges from 0 to 10, with higher scores indicating greater disease severity.
Time frame: change from baseline and 30 minutes after intervention
Quadriceps femoris performance
QF (Quadriceps femoris) strength was evaluated with subjects performing 20 repetitions at the same speed. The protocol established was designed to reach a fatigue threshold in the QF muscle. Dyspnea and perceived level of exertion (Borg scale) were also assessed before and after isokinetic evaluation.
Time frame: change from baseline and 30 minutes after intervention
Biochemical analyzes
Before and after procedures, venous blood samples were collected by a blinded experienced pharmacist to analyze lactate, LDH enzyme, and CK (creatine kinase) concentration. Samples were processed, centrifuged at 3000 rpm for 15 minutes at room temperature. The serum concentration was assessed using a specific enzyme kit for each biomarker, following manufacturer's recommendations.
Time frame: change from baseline and 30 minutes intervention
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.