In recent years, template guidance has been applied and developed in the field of puncture related operations, such as template-assisted radioactive seed implantation. With the guidance of template, needle pathway of seed implantation, biopsy and fiducial marker implantation can be precisely planned , which is conducive to accurate proceeding. Templates can be divided into coplanar templates and non-coplanar templates. The digital coplanar template coordinate puncture system has been developed in China and has been applied in clinical practice. In our previous studies, coplanar template assisted CT-guided radioactive seed implantation has good clinical feasibility for percutaneous biopsy of small pulmonary nodules. However, the accuracy of coplanar template assistance for abdominal tumor puncture are lacking in prospective studies. The study aims to prospectively observe the accuracy and safety of coplanar template assisted CT-guided Pelvic and Groin Areas biopsy.
Study Type
OBSERVATIONAL
Enrollment
30
Peking University Third Hospital
Beijing, Beijing Municipality, China
RECRUITINGBin Qiu, M.D.
Beijing, China
NOT_YET_RECRUITINGAccuracy of Depth
Depth (millimeter) difference between actual puncture and planned puncture pathway
Time frame: during the operation
Accuracy of Angle
Angle (degree) difference between actual puncture and planned puncture pathway
Time frame: during the operation
Success rate of needle puncture
Success rate of needle puncture
Time frame: during the operation
Complication rate
such as pneumoperitoneum, subcutaneous emphysema, hemorrhage, infection, etc.
Time frame: perioperative the operation
operating duration
operating duration from the starting to the ending
Time frame: during the operation
Number of CT scans
Number of CT scans
Time frame: during the operation