Triple-cuffed double lumen endotracheal tube (TC-DLT, ANKOR tube. Insung corp., Korea) which was developed to isolate lung without endotracheal bronchoscope guidance has additional carinal cuff placed between bronchial tube cuff and tracheal tube cuff. This device has been successfully used to isolate lung more simply in specific settings when there is too much excretion to visualize endotracheal structure or for a health provider who is not good at use of traditional double-lumen tube. Although TC-DLT is designed to enable lung separation effectively in situations that confirmation of tube position using bronchoscopy is difficult or not available, but no studies have been conducted on whether effective lung isolation using TC-DLT is possible after change in the relative position of the bronchial tree by postural change. This plan was prepared for research on this.
After enter into operating room, induction of anesthesia is performed through standard general anesthesia procedure before endotracheal intubation. Endotracheal intubation is performed using TC-DLT and inflate carinal cuff with 5 \~ 15ml of air. Then, push it into trachea until resistance is felt. When carinal cuff is placed at carina, deflate carinal cuff and isolate independent lung followed by confirmation of bronchial cuff position using fiberoptic bronchoscopy. Record the location of the bronchial balloon in one of the following conditions 1. at proper position(proximal upper end of bronchial balloon is between 5mm from carinal opening) : 2. proximal end of bronchial balloon is placed more of 5mm distally from carinal opening 3. proximal end of bronchial balloon is placed more of 5mm proximally from carinal opening Then, change patient position to left lateral decubitus (LLD) position and check the position of bronchial balloon using fiberoptic bronchoscopy as previously done. 1. at proper position(proximal upper end of bronchial balloon is between 5mm from carinal opening) : 2. proximal end of bronchial balloon is placed more of 5mm distally from carinal opening 3. proximal end of bronchial balloon is placed more of 5mm proximally from carinal opening After check whether there is something to considerate, end this case.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE
Enrollment
167
After patient's position, 3-cuffed double lumen endotracheal tube is intubated without fiberoptic bronchoscopy guidance
Dongguk University Il-san hospital
Goyang-si, Geyonggi-do, South Korea
RECRUITINGSuccess rate of 3-cuffed double lumen tube inserted in lateral position
Authors insert 3-cuffed double lumen tube after position change to left lateral decubitus with blind fashion. At this time, probability that the tube will be inserted to an appropriate depth is primary endpoint.
Time frame: During procedure(Immediately after secondary intubation)