This is a feasibility, prospective with sequential enrolment, multicenter, clinical investigation in adults and paediatrics with a CE approved Nucleus cochlear implant. Subjects older than 5 years will be included. Subjects will be screened and up to 120 eligible subjects will be recruited in the clinical investigation. Subjects will attend scheduled study visits over a period up to 5 years in different sub-studies as described in the sub-study documentation. A clinical setting can consist of therapeutic elements and evaluations. Subjects will be assessed with the commercially available Nucleus sound processor or via the xPC, NIC, etc. if required. Acute testing will be done where possible. Take home use will be applied when learning effects may play a significant role and to evaluate the acceptance of the new or improved sound coding algorithm or signal processing, in as many listening environments as possible. The subject might also be asked to complete questionnaires, to perform at-home tests etc. during this take home use and/or at the clinical visits. The time for a clinical visit will be limited to a maximum of 4 hours. The time in between clinical visits will vary with typical spacing of between 0 (acute) to 4 weeks. The goals of this umbrella investigation are to measure hearing outcomes to assess performance and/or to achieve higher convenience for implant users and hearing care professionals. The outcomes of the study will guide Cochlear to select features for inclusion in future Nucleus cochlear implant systems and/or future models of care.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
OTHER
Masking
NONE
Enrollment
8
SPACE (Spread Precompensation Advanced Combination Encoder) is a sound coding strategy that is intended to improve spectral resolution, and hence hypothesised to improve cochlear implant (CI) speech understanding in noise. It is an alternative to the ACE sound coding strategy. It has been implemented on the Nucleus 7 CP1000 sound processor for CIC4-based implants.
OPAL-SPACE (combined OPAL and SPACE strategy) aims to preserve as many of the significant features encoded by both OPAL and SPACE strategies individually. Since SPACE codes spectral envelope information, while OPAL codes temporal periodicity information, it is reasonable to suggest that both coding techniques can be combined to improve perception additively.
Advanced Combination Encoder (ACE) is the commercially available, reference sound processing strategy.
For all strategies, programming will be performed using a research version of Custom Sound and the investigational software: Cochlear Device Interface Tool (CDI Tool). Investigational software will be used to stream stimulation sequences to a commercially available N6 sound processor using the Cochlear NIC4.1 interface.
HEARnet Clinical Studies
Carlton, Victoria, Australia
Cochlear Ltd. Melbourne
East Melbourne, Australia
AZ Sint-Jan Brugge-Oostende AV
Bruges, Belgium
Cochlear Technology Centre Belgium
Mechelen, Belgium
Sint-Augustinus Antwerpen
Wilrijk, Belgium
Monosyllabic Word in Quiet Scores.
Monosyllabic word in quiet scores (for conventional Advanced Combination Encoders and new sound coding strategy). Resultant score is percentage of words repeated correctly. Possible scores ranges from 0% to 100% correctly repeated. Higher percentage score means better outcome
Time frame: One Day