Introduction: Prenatal tests can increase the stress levels of pregnant women. One of the tests performed to evaluate fetal health during pregnancy is the Nonstress Test (NST). Objective: To evaluate the effect of NST device noise level on stress parameters in primiparous pregnant women. Method: A randomized controlled, prospective study was conducted with 44 pregnant women in a State Hospital in Istanbul/Turkey between 01.02.2021 and 01.10.2021. Personal Information Form, Spielberger State Anxiety Inventory, Hillrom Welch Allyn Connex Spot Monitor, Gluco Dr Glucometer, Extech SL 400 Personal Noise Dosimeter, Sennheiser HD 450BT ANC Over-Ear Bluetooth Headset, Eppendorf Tube, Philips Avalon FM20 NST were used to collect data. A p value of \<.05 was considered significant in the statistical evaluation.
A number of tests are used to evaluate fetal health during pregnancy. One of these tests is the NST. NST is a frequently used fetal evaluation method in gynecology clinics/services during pregnancy and labor. The sound levels of the NST device are created in a way that the healthcare professional can adjust, and at the same time, the average dB(A) range of the sound levels is not known. It has been stated in many studies that noise causes stress in individuals, and that the stress experienced in pregnant women is associated with negative maternal and neonatal outcomes. It is important to evaluate NST noise levels and stress parameters in order to maintain NST, which is a frequently used fetal evaluation method in the prenatal period in clinical practice, without causing maternal stress and to prevent possible negative consequences. With the information to be obtained in line with the results of the research, it is aimed to maintain the noise level of the NST device used by the midwives in the most appropriate sound range for the pregnant women and thus to ensure that the stress levels of the pregnant women are at the lowest level during the procedure. This study was carried out to evaluate the effect of NST device noise level on stress parameters in primiparous pregnant women.
Study Type
OBSERVATIONAL
Enrollment
44
Pre-Test (0-2 minutes before NST starts) - Measurement of vital parameters (Pre-Test) * Glucose measurement * Taking Salivary Cortisol and Saliva ACTH samples * Filling the Spielberger State Anxiety Inventory • Starting NST by controlling the noise level Interim Test-(NST 10th minute) - Measurement of vital parameters (Intermediate Test) * Taking Salivary Cortisol and Saliva ACTH samples * Filling the Spielberger State Anxiety Inventory • Termination of NST after 20 minutes Final Test(within 0-2 minutes after NST is over) * Measurement of vital parameters * Glucose measurement * Taking Salivary Cortisol and Saliva ACTH samples * Filling the Spielberger State Anxiety Inventory After Data Collection - Recording of data * Centrifugation and analysis of saliva samples taken
Bakırköy Dr. Sadi Konuk Training and Research Hospital
Istanbul, Turkey (Türkiye)
Does increasing the noise level of the NST device affect If salivary cortisol levels
Data collection tool used to reach this outcome: Saliva cortisol was measured by a microplate reader with commercially available kit based on ELISA.
Time frame: 01.02.2021-01.10.2021
Does increasing the noise level of the NST device affect If salivary ACTH levels
Data collection tool used to reach this outcome: Saliva ACTH was measured by a microplate reader with commercially available kit based on ELISA.
Time frame: 01.02.2021-01.10.2021