To date, two devices to measure nitric oxide lung diffusing capacity (DLNO) are commercially available in Europe. Previous research has shown systematic between-device differences in lung diffusing capacity outcomes in healthy people (Radtke et al. ERJ Open Res. 2021 Sep 13;7(3)). The extent and magnitude of between-device differences in people with lung function impairment and ventilation inhomogeneities is unknown.
The aim of this project is to compare two commercially available devices that measure lung diffusing capacity for nitric oxide (DLNO) in people with systemic sclerosis and proven interstitial lung disease. 1. "MasterScreenTM" (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany 2. "HypAir" ("HA", Medisoft, Dinant, Belgium).
Study Type
OBSERVATIONAL
Enrollment
23
Device: Jaeger Masterscreen TM (PFT Pro, Vyaire, Hoechberg, Germany) Device: HypAir Medisoft (Medisoft, Dinant, Belgium)
University of Zurich
Zurich, Canton of Zurich, Switzerland
RECRUITINGDifference in nitric oxide lung diffusing capacity (DLNO in mL.min-1.mmHg-1)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in carbon monoxide lung diffusing capacity (DLCO in mL.min-1.mmHg-1)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in Alveolar volume (VA in L)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in the physiological rate of NO uptake from alveolar gas (KNO in mL.min.-1mmHg-1.L-1)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in the physiological rate of CO uptake from alveolar gas (KCO in mL.min.-1mmHg-1.L-1)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in the rate constant for NO removal from alveolar gas (κNO in s-1)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in the rate constant for CO removal from alveolar gas (κCO in s-1)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in change in fractional alveolar NO concentration (ΔFA NO in ppm)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in change in fractional alveolar CO concentration (ΔFA CO in %)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in breath-hold time (BHT in s)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in inspired concentrations for nitric oxide (%)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in expired concentrations for nitric oxide (%)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in inspired concentrations for carbon monoxide (%)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in expired concentrations for carbon monoxide (%)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in inspired concentrations for oxygen (%)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in expired concentrations for oxygen (%)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in inspired concentrations for helium (%)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour
Difference in expired concentrations for helium (%)
Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).
Time frame: 1 hour