The primary objective of the present study is to evaluate the safety, effectiveness, and clinical outcomes of surgeon-modified fenestrated stent grafts used to treat patients with failed previous infrarenal repairs (failed EVAR) and complex aortic aneurysms (thoracoabdominal, juxtarenal, pararenal, and paravisceral aneurysms).
The study is a prospective, non-randomized evaluation of endovascular repair of patients with failed previous infrarenal repairs (failed EVAR) and complex thoracoabdominal/juxtarenal/pararenal/paravisceral aortic aneurysm repair, including those with penetrating ulcers and aneurysms resulting from aortic dissections, who (1) have anatomy that is not suitable for endovascular repair using grafts currently marketed in the United States, (2) are deemed unsafe to wait the required time necessary for commercial endograft manufacturing, and (3) are at high risk for open surgical repair. Depending on the location of the aneurysm, patients with failed EVAR and complex aortic pathology requiring fenestrated and branched endovascular repair will be treated with physician-modified Cook Zenith devices (Zenith Flex, Zenith Fenestrated stent graft (Zfen), Cook Alpha Thoracic Endovascular Graft, Cook dissection TX2), and their associated commercially approved ancillary components. Whenever possible, the Zenith fenestrated universal bifurcated device will be used for patients requiring repair down to the iliac arteries. The Gore Excluder Endoprosthesis or the Gore Iliac Branch Endoprosthesis (IBE) will be used whenever the Zenith universal bifurcated device is not available. Safety and effectiveness will be assessed acutely (i.e., treatment success and technical success), at 30 days (i.e., the rate of major adverse events (MAE)), at 6 months, at 12 months, and annually to 5 years (i.e., the proportion of treatment group subjects that achieve and maintain treatment success).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
25
Depending on the location of the aneurysm, patients with failed EVAR and complex aortic pathology requiring fenestrated and branched endovascular repair will be treated with physician-modified Cook Zenith devices (Zenith Flex, Zenith Fenestrated stent graft (Zfen), Cook Alpha Thoracic Endovascular Graft, Cook dissection TX2), and their associated commercially approved ancillary components.
Minneapolis Heart Institute Foundation
Minneapolis, Minnesota, United States
Prevention of aortic aneurysm related mortality and all cause mortality post intervention
Primary outcome criteria: * Mortality related to primary aortic disease and intervention * All-cause mortality post intervention
Time frame: 5 years
Issues associated with disease progression, branched instability, endoleak and other disabling complications as evaluated on post-operative follow up and radiographic images.
Secondary outcome criteria (as evidenced on follow up imaging and laboratory tests): * Evidence of aortic disease progression (aneurysm growth \>/=5 mm)
Time frame: 5 years
Endoleak
presence of any endoleak requiring intervention
Time frame: 5 years
Target vessels instability resulting in adverse events to the patient
* mesenteric ischemia * renal failure
Time frame: 5 years
procedure related complication
* stroke * Myocardial infarction * Paraplegia
Time frame: 5 years
Issues associated with device migration and failure
\- Device failure (migration \>/=10 mm)
Time frame: years