The aim of this study is to measure the mesh shrinkage and the visualization of the mesh with MRI scan at 1 month and 13 months after robot assisted preperitoneal hernia repair using the visible CICAT mesh (Dynamesh®).
The study will be conducted in the department of surgery in het AZ Maria Middelares, Ghent, Belgium. Dr. Filip Muysoms will personally select and operate all patients eligible for this study. He will inform all patients about the surgery and the follow-up with MRI scan thereafter. Dr. Beckers will perform all MRI examinations of the patients at 1 month and 13 months post-operatively and will be available for questions from the patient. We want to show that with this type of mesh it is possible to visualize the preperitoneal placed mesh in a safe manner. Furthermore, the positioning of the mesh, mesh shrinkage or mesh shifting will be monitored with this technique. This provides long-term benefit and provides early treatment possibilities in case of post-operative complications related to the mesh position.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
20
Robot assisted laparoscopic preperitoneal repair (vTAPP: ventral transabdominal preperitoneal hernia repair) of a midline ventral hernia
AZ Maria Middelares
Ghent, Belgium
RECRUITINGChange of mesh surface (percentage)
Shrinkage rate / change of the mesh surface (percentage) as measured with the MRI between 1 month and 13 months postoperatively, defined as (100 - mesh surface at 13 months x 100 / mesh surface at 1 month)
Time frame: 1 month and 13 month post-operatively
Change in mesh surface between implantation surface size
Change in mesh surface between implantation surface size, surface at 1m and at 13m
Time frame: 1 month and 13 month post-operatively
Change in mesh width and length between implantation surface size
Change in mesh width and length between implantation surface size, surface at 1m and at 13m
Time frame: 1 month and 13 month post-operatively
Operation duration
Recording of the operation duration needed for robot-assisted ventral TAPP procedure
Time frame: once during operation
Intra-operative complications
Intra-operative complications registered until 4 weeks after the hernia repair
Time frame: until 4 weeks post-operative
Early post-operative complications
Early post-operative complications detected until 30 days after hernia repair
Time frame: until 30 days post-operative
Late complications
Late complications (after 30 days)
Time frame: After 30 days post-operative
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Quality of Life questionnaire
Minimum score is 0, maximum score is 90. The higher the score, the worse the outcome
Time frame: Preoperatively, 30 days, 13 months
Body image score
Minimum score is 0, maximum score is 10. A higher score means a higher level of body image disturbance (worse outcome).
Time frame: Preoperatively, 30 days, 13 months