Pain (nociception), stress and discomfort are difficult to detect in sedated and intubated patients during mechanical ventilation. In order to improve this several nociception level monitors (NOL) were developed that objectively track nociception in sedated or anesthetized patients. Earlier studies showed that for sedated and intubated patients in the operating room, using such monitors is beneficial in reducing stress hormones and post operative pain scores. In this study the investigators aim to observe whether the NOL could be equally beneficial in managing nociception in sedated and intubated ICU patients.
To date it remains challenging to adequately titrate analgesic medication in sedated and anesthetized patients. Recently, nociception monitoring was introduced to guide analgesic treatment in sedated and anesthetized surgical patients. One such monitor is the Nociception Level (NOL; Medasense Biometrics Ltd., Israel). The NOL combines various measurements such as, skin conductance, heart rate, heart rate variability and photoplethysmograph amplitude, and translates these inputs into a single index ranging from 0 (no nociception) to 100 (maximal nociception). Earlier studies have shown that during surgery, the NOL-guided opioid treatment resulted in improved hemodynamics and reduced postoperative pain. In the COVID-19 pandemic, patients admitted in the Intensive Care Unit (ICU), needed excessive amounts of sedatives, analgesics and muscle relaxants during mechanical ventilation. To determine its value in the ICU, the investigators measured NOL values in COVID and non-COVID ICU patients in an earlier study. The aim of the investigators was to verify the assumption that COVID-19 patients were overdosed on opioids. Since the investigators indeed did observe lower NOL values in COVID-19 patients than in non-COVID patients in an earlier study, the investigators expanded the study to determine whether sedatives were equally overdosed, by also measuring the bispectral index (BIS). With this extra information the investigators also hope to determine whether it is feasible to use the NOL in the ICU.
Study Type
OBSERVATIONAL
Enrollment
40
The NOL monitor measures various parameters via a sensor in a finger probe that is attached to the patient. These parameters are: * Temperature * Galvanic skin response * Accelerometer * Photoplethysmograph (pulse rate, pulse rate variability, photoplethysmograph amplitude) All this data is combined in an algorithm which produces a number between 0-100. Between 10-25 indicates adequate analgesia, below 10 too much analgesia, above 25 too little analgesia. No actions are taken based on this measurement.
The BIS processes EEG information to provide a direct measurement of the patient's level of consciousness and insight into the effects of anesthesia on the brain.
The investigators developed a questionnaire with 7-questions regarding the perception of the responsible nurse on the pain of the patient. When the investigators measured for 8 hours with the BIS and the NOL they will ask the nurse what his or her perception was of the pain of the patient. Eventually the investigators will compare the answers of this questionnaire with the NOL and BIS values that they observed, whether the information corresponds or not.
Leiden University Medical Centre
Leiden, South Holland, Netherlands
BIS and NOL values over time
The observation of the BIS and NOL values over time
Time frame: 8 hours
Propofol and opioid dosage
Propofol and opioid dosage will be monitored during 8 hours
Time frame: 8 hours
Feasibility of using the NOL in the ICU
Is it possible to use the NOL on ICU patients and does it monitor correctly
Time frame: 8 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.