The purpose of this study is to assess the effect of three different strategies to inject at reduced volume of contrast medium in Computed Tomography Pulmonary Angiography (CTPA). 330 patients referred for CTPA are randomized to receive either a low-concentration, a low-volume or a saline-diluted injection. Effects on the level and homogeneity of contrast enhancement are measured and compared between groups.
Spectral detector CT facilitates large reductions in contrast medium in vascular CT examinations. To our knowledge, no studies have so far compared different strategies to inject this reduced contrast dose. The purpose of this study is to assess the effect of three different strategies to inject at reduced volume of contrast medium in Computed Tomography Pulmonary Angiography (CTPA). 330 patients referred for clinically indicated CTPA are randomized to receive either a low-concentration, a low-volume or a saline-diluted injection. All patients receive the same amount of iodine (140 mg/kg). Effects on the level and homogeneity of contrast enhancement, image noise, contrast-to-noise-ratio and signal-to-noise-ratio are measured in the CT images and the results are compared between groups.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
TRIPLE
Enrollment
330
Low iodine Spectral Detector CT Pulmonary Angiography
Akershus University Hospital
Lørenskog, Akershus, Norway
Contrast enhancement (Vascular attenuation)
Contrast enhancement measured as attenuation in the pulmonary artery Branches on the acquired CTPA examination
Time frame: Measured on the CT images from the examination performed at enrollment
Homogeneity of contrast enhancement (image noise)
Homogeneity of contrast enhancement is measured as the standard deviation of attenuation in the pulmonary artery branches (equals image noise).
Time frame: Measured on the CT images from the examination performed at enrollment
Contrast to noise ratio (CNR)
CNR is measured as (Vascular attenuation - Muscular attenuation) / Image noise
Time frame: Measured on the CT images from the examination performed at enrollment
Signal to noise ratio (SNR)
SNR is measured as Vascular attenuation / Image noise
Time frame: Measured on the CT images from the examination performed at enrollment