The Best Way to Improve the Near Visual Acuity After ZXR00 IOL Implantation
ZXR00 intraocular lens is a new type of IOL that can achieve good continuous visual acuity. Its characteristic is to improve the distance and intermedia visual acuity and maintain good visual quality while sacrificing the near visual acuity. Previous studies report that there are mainly two ways to improve the near visual acuity of ZXR00:1.Bilateral implantation of ZXR00 with micromonovision. 2. Combined Implantation of ZXR00 and multifocal IOLs.This study aim to explore which is the best way to improve the near visual acuity after ZXR00 IOL implantation.
Study Type
OBSERVATIONAL
Enrollment
30
Uncorrected Visual Acuities
Uncorrected monocular and binocular visual acuities (logarithm of the minimum angle of resolution) at distance (5m), intermediate(66 cm), and near (40 cm).
Time frame: 2022.12.31
Corrected Visual Acuities
Corrected monocular and binocular visual acuities (logarithm of the minimum angle of resolution) at distance (5m), intermediate(66 cm), and near (40 cm).
Time frame: 2022.12.31
Defocus Curve
Corrected monocular and binocular defocus curves were measured from +2.5 D to -4.0 D (in 0.5 D steps).
Time frame: 2022.12.31
Patient satisfaction
Patient satisfaction was rated on a scale of 1 to 5: 1 = very dissatisfied; 2 = dissatisfied; 3 = neutral; 4 = satisfied; and 5 = very satisfied.
Time frame: 2022.12.31
Subjective quality of vision
Subjective quality of vision was evaluated using the 14-item Visual Function Questionnaire (VFQ-14).Each item was scaled according to the degree of difficulty of different activities: 4 points (no difficulty), 3 points (a little difficulty), 2 points (a moderate amount of difficulty), 1 point (a great deal of difficulty), and 0 point (unable to do the activity).overall score is range 0-56.The higher the score, the worse subjective quality of vision.
Time frame: 2022.12.31
Adverse visual symptoms
Adverse visual symptoms including blurred vision, glare, starbursts, haloes, hazy vision, distortion, focusing diffculties, multiple images, and depth perception diffculty, was evaluated using the Quality of Vision test. This test includes 30 items, with a score between 0 and 3 (overall score range 0-90).The higher the score, the more postoperative adverse visual symptoms.
Time frame: 2022.12.31
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Stereopsis
Stereopsis was evaluated using OCULUS Binoptometer.
Time frame: 2022.12.31