Knee osteoarthritis is a debilitating disease that can cause severe knee pain and significant limitations to patients' activities of daily living. Total knee arthroplasty (TKA), also known as knee replacement surgery, is a well-established and successful procedure for treatment of end-stage knee osteoarthritis. Over the years, TKA surgical techniques and implant technology have improved, resulting in better patient outcomes and implant survivorship. Despite continuous improvements being made to this high demand procedure, malalignment of component position is a well-known cause of post-operative complications, including knee pain, component loosening, and failure requiring revision surgery. Advanced techniques that utilize computer navigation or robotic-arm assistance have been developed in an attempt to avoid malalignment. Both technologies were created with the goal of improving the precision of implant positioning and implant sizing in order to improve lower limb alignment and joint line alignment. The OrthoAlign KneeAlign computer assisted navigation system is a commercially available device that uses gyroscopic limb position sensing technology mounted to intramedullary and extramedullary jigs to measure bone resection cuts in TKA that ultimately dictate implant position. The Zimmer Biomet ROSA Knee System is a commercially available, FDA-approved robotic assistant for performing TKA. It uses pre-operative x-rays to create a three-dimensional image of the patient's knee anatomy, which is used to create a pre-operative template of the implants to be used and provides intra-operative guidance for bone cuts during the TKA. The robotic system also assesses the soft tissue envelope around the knee and can assist with the soft tissue balancing of the knee arthroplasty. Alternatively, it can also be used in an imageless mode where bone cuts are performed based on intra-operative mapping using anatomic landmarks. To date, there have been no prospective studies comparing the implant positioning and patient outcomes directly of the KneeAlign system with the ROSA system and conventional TKA instrumentation techniques.
This is a prospective, single center, unblinded, randomized clinical study designed to facilitate the collection and evaluation of workflow efficiency, patient pain and function, adverse event data, and radiographic outcomes for patients undergoing TKA with one of three instrumentation techniques. This clinical study will include Persona and Legion product families using the ROSA Knee System, KneeAlign navigation system, or conventional instrumentation. The primary objective of this study is to collect and compare clinical and surgical data using the commercially available ROSA Knee System instrumentation or OrthAlign KneeAlign system compared with conventional TKA instrumentation. The hypothesis is that the ROSA Knee System and KneeAlign system will demonstrate greater accuracy and more consistent component position and greater patient reported outcome scores compared to conventional TKA surgery. The investigators suspect that the ROSA system may be more accurate and precise than the KneeAlign system. A maximum of 300 subjects in each arm (900 total) are to be enrolled in this study. In order to minimize selection bias, the investigator will randomize the instrumentation technique used. Randomization will be accomplished via a random number generator in a 1:1:1 ratio. The subject will know which treatment arm they are in at the time of study consent. They will be ineligible for the study if they ask to change treatment arms. The Principal Investigator and Co-Investigators will be skilled in TKA and experienced implanting Persona or Legion TKA system. Two of the investigators will only be using the Persona TKA system as this is their current standard of practice. One of the other investigators will use the Legion TKA system as this is their standard of practice. In order to avoid potential selection bias, each investigator will offer study participation to each consecutive eligible patient presenting as a candidate for primary TKA using the aforementioned implants. All study subjects will undergo preoperative clinical evaluations prior to their TKA. An a priori power analysis was conducted using G\*Power 3.1 Data Analysis program to determine the sample size based on a Cohen's f-statistic of 0.25. Power was set at 0.95 and with an alpha of 0.05. Total sample size based on these parameters was 252 patients. Considering that three surgeons, who perform approximately 250 TKAs per year each, will be involved, the investigators estimate that an ability to enroll approximately one-third of all eligible patients seeking TKA and, thus, set a goal for 300 patients to account for patient attrition after study initiation. Through the use of either conventional, computer navigated or robotic techniques, standard operating procedures will be followed and all surgical procedures will be performed under aseptic conditions. Investigators will implant all commercially available components in compliance with corresponding labeling requirements, and in accordance with appropriate surgical technique(s). Post-surgical management for study subjects will follow the investigator's standard of care for patients undergoing TKA (e.g., prophylactic antibiotic therapy, prevention of deep vein thrombosis, prevention of pulmonary embolism, etc.). Post-surgical rehabilitative therapy will be as prescribed by the investigator. Post-operative clinical evaluation will be conducted at approximately 6 weeks, 3 months, 6 months and 1 year post-operatively. Subjects will be followed post-operatively for 1 year.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
The Zimmer Biomet ROSA Knee System is a commercially available, FDA approved robotic assistant for performing TKA. It uses preoperative x-rays to create a three-dimensional image of the patient's knee anatomy which is used to create a preoperative template of the implants to be used and provides intraoperative guidance for bone cuts during the TKA. The robotic system also assesses the soft tissue envelope around the knee and can assist with the soft tissue balancing of the knee arthroplasty. Alternatively, it can also be used in an imageless mode where bone cuts are performed based on intra-operative mapping using anatomic landmarks.
The OrthAlign KneeAlign computer assisted navigation system is a commercially available device that uses gyroscopic limb position sensing technology mounted to intramedullary and extramedullary jigs to measure bone resection cuts in TKA that ultimately dictate implant position.
UCLA Santa Monica Medical Center
Santa Monica, California, United States
Implant Positioning
Radiographic evaluation of post-operative implant positioning compared to pre-operative planning.
Time frame: Pre-Op
Implant Positioning
Radiographic evaluation of post-operative implant positioning compared to pre-operative planning.
Time frame: Up to 6 Hours
Implant Positioning
Radiographic evaluation of post-operative implant positioning compared to pre-operative planning.
Time frame: 6 weeks
Implant Positioning
Radiographic evaluation of post-operative implant positioning compared to pre-operative planning.
Time frame: 3 months
Implant Positioning
Radiographic evaluation of post-operative implant positioning compared to pre-operative planning.
Time frame: 6 months
Implant Positioning
Radiographic evaluation of post-operative implant positioning compared to pre-operative planning.
Time frame: 1 year
Knee Questionnaire
Forgotten Joint Score - 12 questions scored 1 (never) to 5 (mostly). The 12 scores are aggregated to a raw score from 12-60. This raw score is linearly transformed to a 0-100 scale and then reversed to obtain a final score. A high final score indicates a good outcome.
Time frame: Pre-Op
Knee Outcome Score
Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR.) - 7 questions scored from 0 (none) to 4 (extreme). The 7 scores are aggregated to a score from 0-28 which inversely equates to an interval score of 0-100. An interval score of 0 equates to total knee disability and an interval score of 100 indicates perfect knee health.
Time frame: Pre-Op
Health Questionnaire
EuroQol-5 Dimensions-5 Level (EQ-5D-5L) - This consists of a descriptive system and a visual analogue scale (VAS). The descriptive system comprises five questions, scored 1 (no problems) to 5 (extreme problems). The score for each question can be combined into a 5-digit number that describes the patient's health state. A score of 11111 would be optimal. A score of 55555 would equate to complete disability. The VAS is a self-rated vertical scale, from 0 ("the worst health you can imagine") to 100 ("the best health you can imagine").
Time frame: Pre-Op
Objective Knee Assessment
Charnley Functional Classification - An objective knee indicator with 6 possible classifications: Unilateral Knee Arthritis; Unilateral Total Knee Arthroplasty (TKA), opposite knee arthritic; Bilateral TKA; TKA, but remote arthritis affecting ambulation; TKA, but medical condition affecting ambulation; Unilateral or Bilateral TKA with unilateral or bilateral Total Hip Arthroplasty.
Time frame: Pre-Op
Knee Alignment
Anatomic alignment measured on Anterior Posterior (AP) Standing x-ray
Time frame: Pre-Op
Knee Instability Medial/Lateral (M/L)
M/L instability measured in full extension
Time frame: Pre-Op
Knee Instability Anterior/Posterior (A/P)
A/P instability measured at 90 degrees
Time frame: Pre-Op
Joint Motion
Knee Range of Motion measured in degrees
Time frame: Pre-Op
Knee Questionnaire
Forgotten Joint Score - 12 questions scored 1 (never) to 5 (mostly). The 12 scores are aggregated to a raw score from 12-60. This raw score is linearly transformed to a 0-100 scale and then reversed to obtain a final score. A high final score indicates a good outcome.
Time frame: 6 weeks
Knee Outcome Score
KOOS, JR. - 7 questions scored from 0 (none) to 4 (extreme). The 7 scores are aggregated to a score from 0-28 which inversely equates to an interval score of 0-100. An interval score of 0 equates to total knee disability and an interval score of 100 indicates perfect knee health.
Time frame: 6 weeks
Health Questionnaire
EQ-5D-5L - This consists of a descriptive system and a visual analogue scale (VAS). The descriptive system comprises five questions, scored 1 (no problems) to 5 (extreme problems). The score for each question can be combined into a 5-digit number that describes the patient's health state. A score of 11111 would be optimal. A score of 55555 would equate to complete disability. The VAS is a self-rated vertical scale, from 0 ("the worst health you can imagine") to 100 ("the best health you can imagine").
Time frame: 6 weeks
Objective Knee Assessment
Charnley Functional Classification - An objective knee indicator with 6 possible classifications: Unilateral Knee Arthritis; Unilateral Total Knee Arthroplasty (TKA), opposite knee arthritic; Bilateral TKA; TKA, but remote arthritis affecting ambulation; TKA, but medical condition affecting ambulation; Unilateral or Bilateral TKA with unilateral or bilateral Total Hip Arthroplasty.
Time frame: 6 weeks
Knee Alignment
Anatomic alignment measured on AP Standing x-ray
Time frame: 6 weeks
Knee Instability M/L
M/L instability measured in full extension
Time frame: 6 weeks
Knee Instability A/P
A/P instability measured at 90 degrees
Time frame: 6 weeks
Joint Motion
Knee Range of Motion measured in degrees
Time frame: 6 weeks
Patellar Tracking
Investigator assessment of any abnormalities in patellar tracking post-operatively
Time frame: 6 weeks
Patient Satisfaction
Question to be completed by the subject indicating their level of satisfaction with the operated knee as either Very Satisfied, Satisfied, Uncertain, or Unsatisfied.
Time frame: 6 weeks
Knee Questionnaire
Forgotten Joint Score - 12 questions scored 1 (never) to 5 (mostly). The 12 scores are aggregated to a raw score from 12-60. This raw score is linearly transformed to a 0-100 scale and then reversed to obtain a final score. A high final score indicates a good outcome.
Time frame: 3 months
Knee Outcome Score
KOOS, JR. - 7 questions scored from 0 (none) to 4 (extreme). The 7 scores are aggregated to a score from 0-28 which inversely equates to an interval score of 0-100. An interval score of 0 equates to total knee disability and an interval score of 100 indicates perfect knee health.
Time frame: 3 months
Health Questionnaire
EQ-5D-5L - This consists of a descriptive system and a visual analogue scale (VAS). The descriptive system comprises five questions, scored 1 (no problems) to 5 (extreme problems). The score for each question can be combined into a 5-digit number that describes the patient's health state. A score of 11111 would be optimal. A score of 55555 would equate to complete disability. The VAS is a self-rated vertical scale, from 0 ("the worst health you can imagine") to 100 ("the best health you can imagine").
Time frame: 3 months
Objective Knee Assessment
Charnley Functional Classification - An objective knee indicator with 6 possible classifications: Unilateral Knee Arthritis; Unilateral Total Knee Arthroplasty (TKA), opposite knee arthritic; Bilateral TKA; TKA, but remote arthritis affecting ambulation; TKA, but medical condition affecting ambulation; Unilateral or Bilateral TKA with unilateral or bilateral Total Hip Arthroplasty.
Time frame: 3 months
Knee Alignment
Anatomic alignment measured on AP Standing x-ray
Time frame: 3 months
Knee Instability M/L
M/L instability measured in full extension
Time frame: 3 months
Knee Instability A/P
A/P instability measured at 90 degrees
Time frame: 3 months
Joint Motion
Knee Range of Motion measured in degrees
Time frame: 3 months
Patellar Tracking
Investigator assessment of any abnormalities in patellar tracking post-operatively
Time frame: 3 months
Patient Satisfaction
Question to be completed by the subject indicating their level of satisfaction with the operated knee as either Very Satisfied, Satisfied, Uncertain, or Unsatisfied.
Time frame: 3 months
Knee Questionnaire
Forgotten Joint Score - 12 questions scored 1 (never) to 5 (mostly). The 12 scores are aggregated to a raw score from 12-60. This raw score is linearly transformed to a 0-100 scale and then reversed to obtain a final score. A high final score indicates a good outcome.
Time frame: 6 months
Knee Outcome Score
KOOS, JR. - 7 questions scored from 0 (none) to 4 (extreme). The 7 scores are aggregated to a score from 0-28 which inversely equates to an interval score of 0-100. An interval score of 0 equates to total knee disability and an interval score of 100 indicates perfect knee health.
Time frame: 6 months
Health Questionnaire
EQ-5D-5L - This consists of a descriptive system and a visual analogue scale (VAS). The descriptive system comprises five questions, scored 1 (no problems) to 5 (extreme problems). The score for each question can be combined into a 5-digit number that describes the patient's health state. A score of 11111 would be optimal. A score of 55555 would equate to complete disability. The VAS is a self-rated vertical scale, from 0 ("the worst health you can imagine") to 100 ("the best health you can imagine").
Time frame: 6 months
Knee Questionnaire
Forgotten Joint Score - 12 questions scored 1 (never) to 5 (mostly). The 12 scores are aggregated to a raw score from 12-60. This raw score is linearly transformed to a 0-100 scale and then reversed to obtain a final score. A high final score indicates a good outcome.
Time frame: 1 year
Knee Outcome Score
KOOS, JR. - 7 questions scored from 0 (none) to 4 (extreme). The 7 scores are aggregated to a score from 0-28 which inversely equates to an interval score of 0-100. An interval score of 0 equates to total knee disability and an interval score of 100 indicates perfect knee health.
Time frame: 1 year
Health Questionnaire
EQ-5D-5L - This consists of a descriptive system and a visual analogue scale (VAS). The descriptive system comprises five questions, scored 1 (no problems) to 5 (extreme problems). The score for each question can be combined into a 5-digit number that describes the patient's health state. A score of 11111 would be optimal. A score of 55555 would equate to complete disability. The VAS is a self-rated vertical scale, from 0 ("the worst health you can imagine") to 100 ("the best health you can imagine").
Time frame: 1 year
Objective Knee Assessment
Charnley Functional Classification - An objective knee indicator with 6 possible classifications: Unilateral Knee Arthritis; Unilateral Total Knee Arthroplasty (TKA), opposite knee arthritic; Bilateral TKA; TKA, but remote arthritis affecting ambulation; TKA, but medical condition affecting ambulation; Unilateral or Bilateral TKA with unilateral or bilateral Total Hip Arthroplasty.
Time frame: 1 year
Knee Alignment
Anatomic alignment measured on AP Standing x-ray
Time frame: 1 year
Knee Instability M/L
M/L instability measured in full extension
Time frame: 1 year
Knee Instability A/P
A/P instability measured at 90 degrees
Time frame: 1 year
Joint Motion
Knee Range of Motion measured in degrees
Time frame: 1 year
Patellar Tracking
Investigator assessment of any abnormalities in patellar tracking post-operatively
Time frame: 1 year
Patient Satisfaction
Question to be completed by the subject indicating their level of satisfaction with the operated knee as either Very Satisfied, Satisfied, Uncertain, or Unsatisfied.
Time frame: 1 year
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.