To compare the effect between mechanical ventilation strategy guided by transpulmonary pressure and tranditional lung protective ventilation strategy in acute respiratory distress syndrome for right ventricle protection.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
SINGLE
Enrollment
40
Mechanical ventilation parameters adjust guided by transpulmonary pressure monitoring. For pressure assist control or volumn assit control mode; inspiratory pressure or volumn setting needs to maintain Ppeak less than 25 cm H2O; PEEP was set at such a level that expiratory Ptp stayed between 0 and 5 cm H2O.
Beijing Chao-Yang Hospital
Beijing, Beijing Municipality, China
RECRUITINGPulmonary vascular resistance (PVR)
PVR will measured by Swan-Ganz catheter
Time frame: 3 days
Pulmonary vascular compliance
Pulmonary vascular compliance will be calculated using pulmonary artery pressure divided by stroke output measured by Swan-Ganz catheter.