Low flow anesthesia was considered to be causing rebreathing, hypoxia and hypercarbia in the past. However, developing technologies made anesthesia ventilators safer. Low flow anesthesia is proved to be safe and cost-effective for almost a decade, and newer anesthetic machines with automated gas flow and metabolic flow anesthesia (\<0.3 L/min gas flow) features are now becoming prominent. The literature still lacks of pediatric data regarding the cost analysis and safety profile of low flow and especially in metabolic flow anesthesia. In this study, it is aimed to observe inhaled agent expenditure of automated gas flow anesthesia which reaches metabolic flow limits in pediatric patients. For that, automated gas flow will be set to provide a desired end-tidal sevoflurane concentration during general anesthesia. Accordingly, inspired fraction of oxygen and air values will be recorded in 15-minute intervals. Primary outcome will be the inhaled agent (sevoflurane) amount wasted in milliliters for both inhaled agent maintenance speed (8-fast and 4-slow). Secondarily, delta value of set and detected inspired fraction of oxygen (DeltaFiO2=DetectedFiO2-SetFiO2) will be analyzed. DeltaFiO2 higher than 5 units will be accepted as "unsafe" gas mixture, and the incidence will be evaluated. Secondary outcomes will also include duration of emergence from anesthesia including both extubation and obeying verbal commands.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
SCREENING
Masking
NONE
Enrollment
130
General anesthesia will be induced via intravenous agents, and anesthesia maintenance will be provided via inhalation for all the patients. The maintenance will be provided with sevoflurane using automated gas flow with the selected speed of 8. The anesthesia machine indicates amount of sevoflurane inhaled, inspired and exhaled oxygen, carbon dioxyde, air and sevoflurane concentrations. Accordingly these data and actual flow rate will be recorded every 15 minutes.
General anesthesia will be induced via intravenous agents, and anesthesia maintenance will be provided via inhalation for all the patients. The maintenance will be provided with sevoflurane using automated gas flow with the selected speed of 4 (Medium speed). The anesthesia machine indicates amount of sevoflurane inhaled, inspired and exhaled oxygen, carbon dioxyde, air and sevoflurane concentrations. Accordingly these data and actual flow rate will be recorded every 15 minutes.
Istanbul University Istanbul Faculty of Medicine
Istanbul, Turkey (Türkiye)
Total amount of sevoflurane consumed
At the end of the surgery, total amount of sevoflurane, which is indicated on the anesthesia machine screen, will be recorded in milliliters
Time frame: up to 3 hours
Time to extubation after inhalation anesthesia stop
Time between the inhalation anesthesia stop and extubation in minutes
Time frame: Up to 45 minutes
Time to cooperation after inhalation anesthesia stop
Time between the inhalation anesthesia stop and cooperation to verbal impulses in minutes
Time frame: Up to 2 hours
Delta Oxygen Concentration
The adjusted oxygen fraction (generally 40%) minus the actual inhaled oxygen fraction will provide the delta value. The data will be recorded every 15-minute during the surgery, and delta \>%5 will be considered as "unsafe"
Time frame: up to 2 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.