The "Pleiades" study is a non randomised, prospective, single center clinical trial that aims to evaluate the safety and the procedural feasibility of an innovative flow assist device (Pleioflow-RF) in adult patients undergoing elective cardiac surgery.
This is a non randomised, prospective, single center clinical study that aims to evaluate the safety and the procedural feasibility of an innovative flow assist device (Pleioflow-RF) in adult patients, undergoing elective cardiac surgery. The Pleioflow-RF is a percutaneous flow assist device that functions in combination with the traditional Intra Aortic Balloon (IAB). It represents a modified, probably improved, safer and more potent version of the latter, with respect to its dramatic ability to increase renal perfusion in low flow and pressure conditions -as displayed in large animal trials. The Pleioflow RF -IAB assembly integrates two critical elements: (i) a soft Nitinol stent element, positioned at the tip of the IAB, deployed in the descending Aorta that centralizes the IAB, thus preventing excessive IAB movement, protecting the wall of the Aorta from IAB induced injury, and the renal arteries from occlusion, (ii) a downstream valve, mounted within the above stent, that keeps the pressure and flow augmentation, created by the IAB's periodic inflation, localised below said valve, in the abdominal Aorta, where the renal arteries originate. The device is used intraoepratively, during Cardiopulmonary by pass (CPB). During IAB inflation, the IAB occupies space and the pressure increases instantly. The downstream valve above the IAB, receives this pressure wave and closes. The valve closure blocks upstream flow, and diverts all the flow and pressure wave generated by the IAB primarily towards the kidneys and the periphery. Due to the continuous IAB's perdiodic inflation and deflation, the device converts the constant CPB flow and pressure to pulsatile, towards the kidneys. The device is expected to increase substantially the renal perfusion during Cardiac Surgery; it may therefore decrease the post-operative incidence of renal failure. The hypothesis of this clinical study is that the placement of the Pleioflow-RF intraoperatively, particularly in patients who are more prone to developing renal deterioration based on either their Cleveland Clinic prognostic score, or/and the pre-existence of renal impairment, can prevent further renal deterioration in these patients. These vulnerable patients comprise 10-20% of the total cardiac surgery population. Following informed consent, subjects eligible for a elective cardiac surgery that meet all of the inclusion, and none of the exclusion, criteria will be enrolled into the study. The Pleioflow-RF will be inserted preferrably through a 9F sheath into the femoral artery; then advanced into the descending thoracic aorta, and positioned below the origin of the left subclavian artery under transoesophageal echocardiography guidance. Subsequently through the same sheath, the intra-aortic balloon (IAB) will be placed and be advanced up to the proximal tip end of the Pleioflow-RF device. The IABP will be connected to an IAB pump. The duration of operation of the assembly (Pleioflow-RF and the IAB) will be for as long as the cardiopulmonary bypass(CPB) time, in order to protect the kidneys from hypoperfusion, during that time. After the end of the CPB, the IABP and the device will be removed. Subjects will be followed up until 30 days post intervention.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
OTHER
Masking
NONE
Enrollment
40
Subjects who are going to undergo scheduled cardiac surgery and are prone to developing renal insufficiency, will receive the Pleioflow-RF device in conjunction with IABP during CPB. Subjects will be followed until 30-days post-intervention.
Onassis Cardiac Center
Athens, Greece
RECRUITINGFeasibility of the Pleioflow-RF device
Feasibility: Initiation and maintenance the Mean of the maxima (maximum values) of pulsatile pressure ≥65mmHg during cardiopulmonary bypass (CPB)
Time frame: Through end of Device removal procedure
Safety of the Pleioflow-RF device
Safety: Major Device-Related Adverse Events
Time frame: Through end of Device removal procedure
Duration of Intensive Care Unit/Intensive Therapy Unit (ICU/ITU) stay
Time frame: 30 days
Duration of Hospital Stay
Time frame: Up to 30 days postoperative
Acute Kidney injury (AKI)
Time frame: Up to 7 days postopoerative
Need for renal replacement therapy
Time frame: Up to 7 days
Intraoperative and Postoperative use of inotropes and vasopressors
Number of days and dose of inotropes and vasopressors
Time frame: Up to 7 days postoperative
30-Day All-Cause Mortality
Time frame: 30 days
Device- related adverse events
Time frame: 30 days
Evaluation of clinical data.
Recording the haemodynamic data: arterial pressure above and below the device
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Up to 4 hours
Levels of biomarkers.
Recording the following biomarkers levels: Creatinine, Urea, electrolytes and Neutrophil gelatinase associated lipocalin (NGAL)
Time frame: Up to 7 days
Conversion of non- pulsatile to pulsatile flow and pressure during CPB
Time frame: Up to 4 hours
Mean of Maximum pulsatile pressure values peripherally to the valve of the Pleiofow-RF device
Mean of Maximum pulsatile pressure values peripherally to the valve of the Pleiofow-RF device, greater than or equal to 80 mmHg (≥ 80 mm Hg), or increase of Mean of maxima (maximum values of pulsatile pressure), peripherally to the valve of the Pleiofow-RF device≥ 20 mmHg above the mean arterial pressure (MAP) of the non pulsatile flow of the extracorporeal circulation, the latter being recorded 2 minutes prior to the activation of the device
Time frame: Up to 4 hours
Incidence of Pleioflow-RF Device's dysfunction and failures
Time frame: Through end of Device removal procedure
Measure of ease of device insertion delivery, deployment, positioning
Each assessment (insertion, delivery, deployment, and positioning) will be measured independently using the same unit according to the Procedure feasibility score scale as described in the Appendix 1 in the Protocol. A scale (Procedure feasibility score scale as described in the Appendix 1 in the Protocol) will be used to assess the aforementioned outcome. Minimum value is 1 and maximum value is 5, with higher scores stating a better outcome.
Time frame: At time of device insertion
Measure of ease of device removal
A scale (Procedure feasibility score scale as described in Appendix 1 in the Protocol) will be used to assess the aforementioned outcome. Minimum value is 1 and maximum value is 5, with higher scores stating a better outcome
Time frame: Through end of Device removal procedure