Anastomotic complications are serious complications after anus preserving surgery for rectal cancer,the instrument anastomosis technology are one of the factors that influence the occurrence of anastomotic complications after surgery,the laparoscopic linear cutting closure device used in robotic rectal cancer may increase the occurrence of anastomotic complications,but the robot linear cutting stapler (SureForm) may reduce the incidence of postoperative anastomotic complications due to the technical advantages,therefore,the aim of this study is to evaluate the impact of robotic linear cutting stapler SureForm and laparoscopic linear cutting stapler on the incidence of anastomotic complications after robotic rectal cancer anus preserving surgery.
Anastomotic complications are serious complications after anus preserving surgery for rectal cancer, including anastomotic leakage, anastomotic bleeding, and anastomotic stenosis, with a incidence rate of 1.6% - 20.5% . The occurrence of anastomotic complications increases the perioperative mortality, hospital stay, and hospital costs of patients, and even some patients with severe anastomotic complications need to be re operated after surgery, which seriously affects the quality of life of patients. More research shows that , The complications of anastomotic stoma lead to the delay of postoperative adjuvant therapy, which increases the local recurrence rate of tumor. Therefore, how to reduce the occurrence of anastomotic complications in anus preserving surgery for rectal cancer has always been the focus of surgeons. A variety of factors are involved in the occurrence of anastomotic complications after surgery, including gender, patient's general condition, tumor size and distance from anal margin, and instrument anastomosis technology . It is believed that , when using a closer to break the rectum during radical resection of rectal cancer, the use of multiple nail cages will increase the incidence of postoperative anastomotic complications. In the past, laparoscopic rectal cutting staplers were used in robotic radical resection of rectal cancer, and most of them were completed with the cooperation of assistants. In difficult cases, the mechanical arm needed to be removed and the main knife was used to perform rectal resection. In addition, the laparoscopic linear cutting closure device was cumbersome and complicated, and it often needed to use multiple nail silos to cut rectum in a narrow pelvic cavity, resulting in uneven anastomosis quality, Increase the occurrence of anastomotic complications. In recent years, the robot company has developed a new software driven robot assisted stapler (SureForm). The stapler can be directly loaded onto the mechanical arm. When the rectum is broken, the main knife can independently control it on the console. It has a joint head that rotates 60 ° from top to bottom, left to right, a 120 ° cone range of motion, and a 540 ° wrist joint design of the rod body, so that the stapler jaws can be vertically placed and separated from the rectum, The utility model can reduce the use of the nail bin when the rectum is transected, thereby reducing the incidence of postoperative anastomotic complications. At present, only a few foreign studies have reported the application of robot linear cutting stapler SureForm in anus preserving surgery for rectal cancer, and the studies are retrospective, with a small sample size. There is no report in China. Therefore, this study adopts a prospective randomized controlled study method to evaluate the impact of robotic linear cutting stapler SureForm and laparoscopic linear cutting stapler on the incidence of anastomotic complications after robotic rectal cancer anus preserving surgery, so as to provide a reference for the application of robotic linear cutting stapler SureForm in robotic anus preserving surgery.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
276
Da Vinci linear cutting stapler
Taiyuan li
Nanchang, Jiangxi, China
Incidence of anastomotic complications
Anastomotic leakage and anastomotic bleeding
Time frame: 1 month after surgery
The number of stapler cartridges required for rectal transection
number per each surgery
Time frame: 1 month after surgery
operative time
minute
Time frame: 1 month after surgery
operative blood loss
milliliter
Time frame: 1 month after surgery
Time to first flatus
days
Time frame: 1 month after surgery
Postoperative length of stay
days
Time frame: 1 month after surgery
Distal resection margin
centimeter
Time frame: 1 month after surgery
proximal resection margin
centimeter
Time frame: 1 month after surgery