The aim of this controlled randomized crossover study is to compare the physiological effects of nasal high flow therapy (NHF) with 2 different nasal cannulas in patients with exacerbated chronic obstructive pulmonary disease (ECOPD) and chronic respiratory failure. 20 patients will be treated with NHF therapy (Airvo, Fisher\&Paykel Healthcare, NZ) during wakefulness. Physiological measuremends will take place over three perdiods (visits). One period without NHF, one with NHF via standard cannula (Optiflow M) and one with asymmetrical cannula (Optiflow Duet) in randomised order.
Background: Nasal High Flow (NHF) therapy had shown to increase airway pressure, reduce dead space, and improve mucociliary clearance and gas exchange in patients suffering from chronic obstructive pulmonary disease (COPD). The long-term and short-term physiological aspects of NHF are subject of ongoing research. Different flow rates and cannula sizes have been studied and found to yield different therapeutic effects. Larger sized cannulas tend to seal the nares and produce increased positive airway pressure, while smaller cannulas increase the washout effect. Currently, a new cannula is available, with one smaller and one larger opening (Optiflow+ Duet, Fisher\&Paykel Healthcare, NZ). Procedure: Following a baseline period without high flow therapy, NHF (35L/min) will be applied via the nasal cannula (Duet or Standard in randomized order). After a wash out phase, the NHF interface will be replaced for another measurement with the respective other cannula (Standard or Duet). Respiratory rate, tidal volume, minute ventilation, inhalation to exhalation ratio (Ti/Te), transcutaneous pCO2 and intercostal EMG will be recorded during each partial measurement.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
20
Patients with chronic obstructive pulmonary disease and chronic respiratory failure use Nasal High Flow therapy during daytime sessions of 1.5 h.
Georg N Nilius
Essen, North Rhine-Westphalia, Germany
RECRUITINGChange in minute ventilation (MV) comparing arm 1 and 2
Respiratory effort measured with calibrated RIP system (Respitrace QDC; Viasys Services, Lakeland, FL), MV is calculated. Unit is L
Time frame: 1.5 hours
Change in respiratory rate (RR) comparing arm 1 and 2
Respiratory effort measured with calibrated RIP system (Respitrace QDC; Viasys Services, Lakeland, FL), RR is calculated. Unit is breath per minute
Time frame: 1.5 hours
Change in inhalation to exhalation ratio (Ti/Te) comparing arm 1 and 2
Respiratory effort is measured with calibrated RIP system (Respitrace QDC; Viasys Services, Lakeland, FL), (Ti/Te) is calculated.
Time frame: 1.5 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.