This is an investigator-initiated, cluster randomized controlled trial. The primary objective is to compare the diagnostic yield of the Ion™ Endoluminal System (SSCB) to the ILLUMISITE™ Platform (EMN bronchoscopy) in patients undergoing bronchoscopy for peripheral pulmonary lesion (PPL) evaluation.
Peripheral pulmonary lesions (PPLs) are often biopsied to assess for the presence of infection, inflammation, or malignancy. Tissue can be acquired in a variety of ways: surgical resection, percutaneous transthoracic needle biopsy, or bronchoscopic biopsy. Bronchoscopy is commonly pursued to determine PPL etiology, with over 500,000 performed annually in the US alone. Advanced imaging and navigational guidance systems are required to accurately approach small peripheral lesions bronchoscopically. A variety of navigational technologies are currently available, including electromagnetic navigational bronchoscopy (EMN), virtual bronchoscopy, thin and ultrathin bronchoscopes, and endobronchial ultrasound. No comparative data exist regarding the relative performance of these competing technologies, which are all considered standard of care and currently used interchangeably based on personal preferences and availability. EMN platforms dominate the current navigational bronchoscopy market. The largest prospective multicenter study assessing EMN performance showed a diagnostic yield of 73%. The more recent addition of intraprocedural digital tomosynthesis has been reported to increase EMN diagnostic yield to 75-83%; this feature is included in the ILLUMISITE™ electromagnetic navigational bronchoscopy platform (Medtronic, Minneapolis, MN, U.S.) and is labeled "fluoroscopic navigation". Recently, the FDA cleared a novel navigational technology: shape-sensing catheter bronchoscopy (SSCB), via the 510(k) pathway. This pathway requires a technical demonstration of safety and efficacy similar to that of an existing predicate device but does not usually require clinical data. Since market release in 2019, single-center prospective cohort data have emerged suggesting SSCB diagnostic yield is comparable to EMN, but no high-quality comparative data exist regarding the relative performance of these two technologies. Despite this important knowledge/data gap, SSCB has become a popular platform in the advanced bronchoscopist community. High-quality comparative data are required to inform optimal patient care. Additionally, EMN and SSCB platforms are considered capital purchases, each costing hundreds of thousands of dollars. Hence, it is also important for health care systems to have high quality data as they consider device purchases. VUMC currently utilizes both SSCB and EMN and they are used interchangeably in our two operating rooms. Patients are typically assigned arbitrarily to procedures using either platform based on operating room availability. Thus, the investigator proposes a randomized controlled study to test the hypothesis that the diagnostic yield of SSCB is not inferior to EMN in patients undergoing bronchoscopy to biopsy a PPL.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
DOUBLE
Enrollment
447
Providers will utilize the ILLUMISITE™ Platform (EMN) machine to perform a diagnostic bronchoscopy procedure.
Providers will utilize the Ion™ Endoluminal System (SSCB) machine to perform a diagnostic bronchoscopy procedure.
Vanderbilt University Medical Center
Nashville, Tennessee, United States
Diagnostic Yield
Diagnostic yield is defined as the proportion of procedures that results in acquisition of lesional tissue. Lesional tissue is defined by the presence of histopathological findings that readily explain the presence of a pulmonary lesion. The following common histopathological findings are pre-specified as lesional: i. Malignant ii. "Specific benign" findings accounting for the presence of a PPL 1. organizing pneumonia, or 2. frank purulence/robust neutrophilic inflammation, or 3. granulomatous inflammation, or 4. other specific benign finding findings such as hamartoma, amyloidoma or other uncommon causes of PPLs with distinctive pathological patterns.
Time frame: 7 days post-enrollment
Duration of Procedure
Defined as time from the start of airway registration to the removal of the bronchoscope after completion of navigation procedures
Time frame: Duration of procedure, approximately 60 minutes