In this prospective, post-market, multi-site, open-label, crossover trial, women with urinary incontinence requiring the use of diapers (changes complets (French term)) at night will be 1:1 randomized to a treatment sequence using two devices (PureWick™ System and Hollister® Female Urinary Pouch External Collection Device) and followed for approximately 10 weeks through 2 treatment phases. The primary objectives are to evaluate safety (skin injury) and efficacy (capture rate). Safety will be assessed using the Draize Scale and efficacy will be measured based on daily urine capture rate.
In this prospective, post-market, multi-site, open-label, crossover trial, women with urinary incontinence requiring the use of diapers (changes complets (French term)) at night will be 1:1 randomized to a treatment sequence using two devices (PureWick™ System and Hollister® Female Urinary Pouch External Collection Device) and followed for approximately 10 weeks through 2 treatment phases. Approximately 30 female participants from 2 sites will be enrolled into the study. Those meeting eligibility criteria will be treated according to the treatment sequence assigned during randomization. Participants will view the standardized training video for the applicable product at the beginning of each treatment phase and have access to the Information for Use document (IFU) to review during each treatment phase. The total expected duration of subject participation is approximately 10 weeks. Participants will use the device assigned in treatment phase 1 overnight while sleeping for 4 weeks (28 days) before transitioning to the second assigned device in treatment phase 2. There will be a minimum washout period of 2 weeks (not to exceed 4 weeks) between treatment phases and a re-screening of eligibility criteria before the second phase. In both treatment phases, participants will independently place and remove the FEC (female external catheter) or FUP (Female Urinary Pouch) after standardized teaching is completed on the first day of the treatment phase. The primary objectives are to evaluate safety (skin injury) and efficacy (capture rate). Safety will be assessed using the Draize Scale and efficacy will be measured based on daily urine capture rate. Health Care Providers (HCPs) will visit participants' homes daily to perform a skin assessment and collect urine measurements during the treatment phases. Participants will be withdrawn from the treatment phase if grade 4 is achieved in any category on the Draize skin irritation scale. The secondary objectives are to assess quality of life, tolerability, comfort and ease of use. Quality of life and comfort and ease of use will be measured using self-reported changes in quality of life via the validated Nocturia Quality of Life (N-Qol) tool \& the PROMIS Sleep Disturbance Short-form 4a survey, and subjective evaluation of the therapy via participant survey, respectively. Tolerability will be measured by number of days of actual use of both devices, and discontinuation rate attributed to the device's discomfort or inconvenience.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
NONE
Enrollment
17
The PureWick™ FEC is intended for non-invasive urine output management in female patients. The PureWick™ FEC is a flexible, contoured external catheter that is positioned against the area where urine exits the female body. The PureWick™ FEC is connected to the PureWick™ Urine Collection System (PUCS) via connector tubing. The PUCS uses suction (not felt by the user) to pull voided urine through the device, regardless of the urine flow rate. Urine continues through vinyl tubing until it reaches a collection canister, away from the body.
The Hollister Female Urinary Pouch External Collection Device is intended to collect and contain urine for individuals with urinary incontinence. It is designed to be emptied and should be attached to a drainage bag. The FUP is made with hydrocolloid skin adhesive and polymer/copolymer plastics.
Smiths Medical Center
Dunwoody, Georgia, United States
Weill Cornell Medical Center
New York, New York, United States
Daily Average Urine Capture Rate (Percentage)
Capture rate following void (captured as % of urine captured by device and collected in canister, measured by weight). Prior to each nightly use, the weight of the empty urine collection canister and the weight of a dry absorbent pad are collected. Participants use the device overnight while sleeping with the absorbent pad underneath them. The next morning, the post-void weight of the urine collection canister and the post-void weight of the absorbent pad are collected. Capture rate is calculated as the weight of captured urine (post-void canister weight - pre-void canister weight) / total urine volume (captured urine (post-void canister weight - pre-void canister weight) + leaked urine (post-void pad weight - pre-void pad weight)) \* 100. The primary efficacy endpoint of urine capture rate is derived by computing the mean of daily capture rate during each study phase.
Time frame: Daily for 28 days during each treatment phase
Daily Average Skin Irritation Score Using the Draize Scale
Draize Scale is a 5 point scale where 0 is no erythema, edema, or bleeding and 4 is severe erythema, edema, and/or bleeding. The primary safety endpoint of skin irritation score is derived by computing the mean of Draize Scale scores assessed daily during each study phase.
Time frame: Daily for 28 days during each treatment phase
Nocturia Quality of Life (N-QOL) Score
N-QOL is a standardized tool used to explore 13 items that might be affected by nocturia (e.g., concentration, productiveness, and low energy). Transformed Total Score is computed from the core 12 item summary scores and ranges from 0-100 with higher scores indicating better quality of life.
Time frame: Starting at baseline and then every 2 weeks during each treatment phase
PROMIS Sleep Disturbance - Short Form 4a Score
The PROMIS Sleep Disturbance Short Form 4a consists of 4 questions that each have 5 response options, with 1 indicating the least sleep disturbance and 5 indicating the most sleep disturbance. Total raw scores are translated into a T-score ranging from 32.0 to 73.3, with higher scores indicating worse outcome.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Starting at baseline and then every 7 days during each treatment phase
Participant's Tolerability of Device/Treatment
Participant's tolerability is determined by the number of days of actual device use.
Time frame: After completion of the 28-day treatment phase or at the time of treatment discontinuation, whichever comes first.
Participant's Comfort Level Associated With Device/Treatment
Overall comfort on a 5-point Likert scale ranging from 1- 5 with higher scores indicating a better outcome, where 1 = Very Uncomfortable, 2 = Uncomfortable, 3 = Neither Comfortable nor Uncomfortable, 4 = Comfortable, and 5 = Very Comfortable. The last question related to likelihood to recommend the device ranged from 1-5 with higher scores indicating a better outcome, where 1 = Very Unlikely, 2 = Unlikely, 3 = Neither Likely nor Unlikely, 4 = Likely, and 5 = Very Likely.
Time frame: After completion of each 28-day treatment phase or at the time of treatment discontinuation, whichever comes first.
Participant's Opinion of Ease of Device Use
Ease of use score on a 5-point Likert scale ranging from 1- 5 with higher scores indicating a better outcome, where 1 = Very Difficult, 2 = Somewhat Difficult, 3 = Average Difficulty, 4 = Somewhat Easy, and 5 = Very Easy. The last question related to dryness experienced with the device during sleep ranged from 1-4 with higher scores indicating a better outcome, where 1 = Never Dry, 2 = Sometimes Dry, 3 = Usually Dry, 4 = Always dry to mostly always dry
Time frame: After completion of each 28-day treatment phase or at the time of treatment discontinuation, whichever comes first.