Pediatric patients with distal radius fractures are most commonly treated non-operatively with fracture reduction and cast immobilization. In order to prevent complications from increased swelling after the injury (or fracture manipulation) casts may be split along their length to relieve pressure. However, this can compromise the casts' structural integrity, predisposing fractures to loss of reduction. The goal of this study was to investigate if cast bivalving, or splitting the cast longitudinally on both sides, resulted in any immediate change to bony alignment and to assess if bivalving effected cast parameters associated with loss of reduction.
Displaced pediatric distal radius fractures are treated with fracture reduction and cast immobilization. Currently, at our institution (and many others) radiographic assessment to determine acceptable fracture alignment and cast parameters is done immediately after cast application. However, afterward casts are often split on both sides along their length, in a process known as bivalving, prophylactically treating for post-traumatic soft tissue edema. While bivalving is felt to relieve pressure from the cast, it may also diminish the structural integrity of the cast. Although it is well-established that loss of fracture alignment is most common in the first few weeks after fracture reduction there have been no studies to evaluate any immediate changes to fracture reduction or cast parameters that may occur after bivalving. Thus, the goal of this study was to assess if pediatric distal radius fracture alignment was affected by cast bivalving by obtaining post-bivalve radiographs in addition to standard post-cast radiographs.
Study Type
OBSERVATIONAL
Enrollment
60
2 view plain film of forearm after valving a short arm cast.
Brooke Army Medical Center
Fort Sam Houston, Texas, United States
Change in reduction after bivalving
Change in fracture reduction of 2mm or 5 degrees in angulation on radiographs after bivalving
Time frame: up to 24 hours
Change in reduction at follow-up
Change in fracture reduction of 2mm or 5 degrees in angulation on radiographs at follow-up
Time frame: up to 30 days
Cast Index
Cast index, the ratio of sagittal to coronal width from the inside edges of the cast at the fracture site will be measured via radiographs.
Time frame: through study completion, up to 2 years
Gap Index
Gap index is a measure of space between the cast and skin measured as a ratio to the inside diameter of the cast, assessed at the level of the fracture on anteroposterior and lateral radiographs.
Time frame: through study completion, up to 2 years
Three Point Index
Three point index, a measure of space between the cast and skin at sites of the three point mold, with reference to the adequacy of reduction, assessed via the contact length of the proximal and distal fracture segments on anteroposterior and lateral radiographs.
Time frame: through study completion, up to 2 years
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.