The goal of this pivotal study is to demonstrate the safety and performance of the Cor TRICUSPID ECM (extracellular matrix) Valve (or Cor PEDIATRIC Tricuspid ECM Valve) for the surgical management of tricuspid valve disease and dysfunction in adult and pediatric patients. The main question(s) it aims to answer are: * whether the device may be implanted successfully and safely, and * whether the device effectively treats tricuspid valve disease and dysfunction through 12 months Participants will undergo: * preoperative evaluation * tricuspid valve replacement with the Cor TRICUSPID ECM Valve * postoperative evaluation, including at hospital discharge, 30 days, 6 months, and 12 months, and then annually thereafter through 5 years
CorMatrix Cardiovascular, Inc. has developed a device for heart valve replacement, the Cor TRICUSPID ECM Valve for adults and the Cor PEDIATRIC Tricuspid ECM Valve for pediatrics (collectively these devices will be referred to as the Cor TRICUSPID ECM Valve(s)), which can be implanted to replace dysfunctional tricuspid heart valves. The objective of this Pivotal Study is to collect safety and effectiveness data on surgical tricuspid valve replacement procedures using the Cor TRICUSPID ECM valve to support a Humanitarian Device Exemption (HDE) marketing application. Because the majority of tricuspid valve replacements (TVRs) (approximately 80%) are performed concomitantly with other cardiac operations, including replacements of mitral or aortic valves, it is anticipated that a portion of study subjects will require concomitant replacement or repair of a dysfunctional mitral or aortic valve, based on the clinical judgment of the investigator. Therefore, safety with the Cor TRICUSPID ECM Valve will be established by Procedural, Technical and Device Success.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
92
Tricuspid valve replacement with the Cor TRICUSPID ECM Valve for the surgical management of tricuspid valve disease or dysfunction.
St Francis Hospital
Indianapolis, Indiana, United States
RECRUITINGColumbia University Irving Medical Center/New York Presbyterian
New York, New York, United States
RECRUITINGSafety Outcome - Procedural Success
Device Success and no tricuspid valve device-related Serious Adverse Events (SAEs)
Time frame: 30 days
Effectiveness Outcome - Individual Patient Success
* Device success and * no Cor TRICUSPID ECM Valve-related re-hospitalizations or re-interventions of the Cor TRICUSPID ECM Valve (clinically significant: new endocarditis of the tricuspid valve \[TV\], recurrence of tricuspid regurgitation \[TR\] \> moderate, or right sided heart failure \[HF\]) unless endocarditis is secondary to recurrent drug abuse. * Improvement vs. baseline in symptoms (improvement in New York Heart Association \[NYHA\] \[adult subjects\] and clinical improvement \[pediatric subjects\] Class \>/= 1 grade)
Time frame: 6 months
Effectiveness Outcome - Individual Patient Success
* Device success and * no Cor TRICUSPID ECM Valve-related re-hospitalizations or re-interventions of the Cor TRICUSPID ECM Valve (clinically significant: new endocarditis of the tricuspid valve \[TV\], recurrence of tricuspid regurgitation \[TR\] \> moderate, or right sided heart failure \[HF\]) unless endocarditis is secondary to recurrent drug abuse. * Improvement vs. baseline in symptoms (improvement in New York Heart Association \[NYHA\] \[adult subjects\] and clinical improvement \[pediatric subjects\] Class \>/= 1 grade)
Time frame: 12 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.