An immediate perioperative parameter that assess the integrity of the Erythrocytes Membrane and therefore their structural quality isn't available in clinical practice and medical diagnostics except through indirect clinical biochemical tests or through the scanning electron microscope. The red blood cell (RBC) membrane contains proteins and glycoproteins embedded in a fluid lipid bilayer that confers viscoelastic behavior. Sialylated glycoproteins of the RBC membrane are responsible for a negatively charged surface which creates a repulsive electric zeta potential (ζ) between cells. These charges help prevent the interaction between RBCs and the other cells and especially between each other. The zeta potential is a physical property which is exhibited by all particles in suspension. The development of a net charge on any particle affects the distribution of ions in the surrounding interfacial region resulting in an increased concentration of counter ions of opposite charge to that of the particle, close to the surface. In this context we present a new parameter that studies the interactions of the Erythrocytes membrane treated with positive ions and their maintenance of the charge. We compared the measured polarization values with the Erythrocyte Sedimentation Rate (ESR), expression of speed with which RBCs tend to settle inside a particular graduated capillary called Westergren's tube and Plasma Free Hemoglobin (pFHb).
Study Type
OBSERVATIONAL
Pre and perioperative data blood sample were collected for each patient 5 minutes (min) before the CPB start and 5 minutes before the end of the CPB for Complete Blood Count (CBC), Erythrocyte Sedimentation Rate (ESR) and Plasma Free Hemoglobin (pFHb). At the end of CPB the residual blood from the extracorporeal circulation was treated with cell-saver and the treated and concentrated red blood cells were collected in a transfusion bag. Two milliliters (ml) was taken from the bag, one ml was subjected to a blood gas test for the evaluation of the Hemoglobin (Hb) content and one ml was subjected inside a cuvette to the release of positive ions (polarization) with a charge of 50 Millivolt (mV) for a time of 5 seconds through charge circuit, after the trend of the conserved charge was measured through a multimeter, instrument that can measure multiple electrical properties.
Anthea Hospital
Bari, Italy
Erythrocytes Membrane Integrity
Conservation of charge after polarization
Time frame: At the end of Cardiopulmonary Bypass
Erythrocyte Sedimentation Rate (ESR)
Inflammation
Time frame: At the end of Cardiopulmonary Bypass
Plasma Free Hemoglobin (pFHb)
Hemolysis
Time frame: At the end of Cardiopulmonary Bypass
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.