The goal of this multi-center, cross-sectional, observational study is to test and compare the difference of the supraspinatus tendon's elasticity between diabetics and healthy people. The main questions it aims to answer are: * Ultrasonic characteristics of supraspinatus tendon in diabetic patients * Influencing factors of elastic value and thickness of supraspinatus tendon Participants will be asked to: * Perform ultrasound examination of the shoulder join. * Fill in a survey with certain questions on their basic information.
Study Type
OBSERVATIONAL
Enrollment
361
Shear wave ultrasonic imaging technique was used to measure the superficial and deep shear wave velocity of supraspinatus tendon at 10mm (distal end) and 15mm (proximal end) from the attachment end of the greater tubercle of the humerus on the long axis section of supraspinatus tendon.
Guangdong second provincial general hospital
Guangzhou, Guangdong, China
RECRUITINGElasticity of the supraspinatus tendon
After activating the SWE mode, the elastic image was generated in the two-amplitude mode. After the image quality mode was qualified (the color curve in the figure was smooth), Shear wave velocity in the superficial and deep layers of the supraspinatus tendon were measured at the distal and proximal ends of the tendon perpendicular to the surface of the humerus, respectively.
Time frame: 10 mins
Thickness of the supraspinatus tendon
The thickness of the supraspinatus tendon was measured at a tangent line perpendicular to the surface of the humerus 15mm from insertion.
Time frame: 2 mins