Statement of the problem: Based on the literature traditional immediate implant with immediate loading has high failure rate due to destructive horizontal forces, accordingly It was recommended for long time stress-free healing periods to achieve the osseointegration of dental implants. But unfortunately this long time to restore the missing teeth is unsatisfactory to the patient due to high increase of patients' demand for perfect restoring missing teeth preservation of soft and hard tissues with better esthetic and functional results with decreasing the treatment plan time. Rationale for conducting the research: This study aimed to add a satellite implant device around the root form implant to enhance the primary implant stability for immediate loading followed by assessment of the final implant stability and final bone quantity and quality around the placed implant
Research question: Does the use of satellite implant technique for immediate loading will effectively reduce the treatment time without affection of the final implant stability and the final bone quality and quantity around the placed root form dental implant? Statement of the problem: Based on the literature traditional immediate implant with immediate loading has high failure rate due to destructive horizontal forces, accordingly It was recommended for long time stress-free healing periods to achieve the osseointegration of dental implants. But unfortunately this long time to restore the missing teeth is unsatisfactory to the patient due to high increase of patients' demand for perfect restoring missing teeth preservation of soft and hard tissues with better esthetic and functional results with decreasing the treatment plan time. Rationale for conducting the research: This study aimed to add a satellite implant device around the root form implant to enhance the primary implant stability for immediate loading followed by assessment of the final implant stability and final bone quantity and quality around the placed implant Review of literature: A long time before there is increase of the patient demand for perfect restoring missing teeth with reducing the total time of treatment over all. So immediate loading implant was a very good solution especially in esthetic zone . However , it is not always applicable due to the difficult surrounding circumcenters Such like unfavorable type or quality of bone which makes immediate implant is impossible. Osseointegration of an implant, which is the main treatment goal, might best be understood to simply mean "undisturbed bone healing around the implant." Micro motion probably interferes with the development of an adequate early scaffold from the fibrin clot . Biomechanically, implants to be loaded immediately need to be stable and resistant to macro movement to ensure good osseointegration. Enhancement of implant stability can be achieved primarily by using a connecting bar as a stabilizer to provide a polygonal support to distribute forces and moments on single standing implants . This study aimed to add a satellite plate around the root form implant to enhance the primary implant stability for immediate loading followed by assessment of the final implant stability and final bone quantity and quality around the placed implant. Objectives: This study aimed to evaluate the final implant stability and bone condition after the use of satellite immediate implant with immediate loading in fresh extraction sockets.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
6
Infiltration anesthesia will be administered using mepivacaine HCl (2%) with levonordefrin 1:20 000 . Injection to control pain and bleeding for hemostasis. Dental extraction will be done with minimal force to avoid trauma to the bone. Flab will be released, different drilling sizes will be used to attain the final drill size of the planed implant height and width according to Cone Beam CT. Implants were screwed directly into the osteotomy site, a satellite implant device is attached to the implant's abutment placed on the buccal and palatal plates of bone and retention between the abutment and microplate will help in neglecting the lateral destructive forces . sutures will be done . Impression will be taken for immediate loading with the final crown. Cone beam will be done.
Cairo university ,
Giza, Egypt
final implant stability after satellite implant device removal.
OUT COME Calculate the final implant stability after plate removal. MEASURE DEVICE Osstell "resonance frequency analyzer" MEASURE UNIT ISQ
Time frame: 6 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.