The goal of this randomized clinical trial is to compare diagnostic results of secondary breast cancer surveillance using breast ultrasound abbreviated MRI and full protocol MRI.
Women who have been treated for breast cancer are at risk of ipsilateral local/regional recurrence or new primary cancers in the contralateral breast, which are associated with increased rates of distant metastases and breast cancer mortality. The goal of post-treatment imaging surveillance is to detect early second breast cancer, which permits interventions to improve survival and maintain quality of life. Currently, most guidelines consistently recommend annual mammography for women with a personal history of breast cancer (PHBC). However, in women with dense breasts, mammographic sensitivity decreased from a level of 85.7%-88.8% in patients with almost entirely fatty tissue to 62.2%-68.1%. Even more, sensitivity of mammography was lower in women with a PHBC within the initial 5 years after primary breast cancer (PBC) treatment. In addition, dense breasts lead to an increased percentage of interval cancer. Thus, the need for a better surveillance modality has emerged. In this context, breast US may be considered as a supplemental screening modality because it is widely available, does not need contrast agents, and is of relatively lower cost . A few studies indicate that adding screening US to mammography reduced interval cancer rates for women with dense breasts and enable detection of early-stage cancers at an average of 4.2 cancers per 1000 US examinations. As an another candidate, breast MRI shows high sensitivity and offers the highest cancer detection rate but its routine usage in women with a PHBC is still on debate. Another possible imaging modality is breast magnetic resonance imaging (MRI). Current National Comprehensive Cancer Network (NCCN) guidelines suggest annual screening with mammography and MRI is recommended for ① women with Breast Cancer Susceptibility Gene (BRCA1 or BRCA2) mutations, ② first-degree family members of carriers of BRCA mutations, ③ women with a lifetime risk of breast cancer greater than 20% based on family history, and ④ women have radiotherapy for thorax at the age of 10-30 years and ⑤ women diagnosed with lobular carcinoma in situ (LCIS), atypical ductal hyperplasia (ADH), or atypical lobular hyperplasia (ALH) by previous biopsy. And, this is based on the results of existing single-center or multi-center prospective studies. Women who underwent breast-conserving surgery for breast cancer before the age of 50 were added to the 2018 new MRI screening group of the American College of Radiology (ACR), and their secondary breast cancer risk is 20% or more. Most women with a history of breast cancer have an intermediate risk (\>15% but \<20%) of developing breast cancer. Therefore, when most patients are not in the high-risk group, performing conventional MRI (full-protocol MRI, FP-MRI) for all postoperative examinations is not appropriate in terms of cost and time. Abbreviated MRI (AB-MRI), introduced relatively recently, is a method designed to increase accessibility by reducing time and cost by selectively capturing only some sequences in FP-MRI. Sequence composition can be adjusted in various ways, and image acquisition must be completed within 10 minutes. A number of studies have demonstrated that AB-MRI has comparable diagnostic results to FP-MRI. The most recent paper published in Korea compared the scores of 726 patients with AB-MRI and FP-MRI by performing propensity score matching. The results were comparable in sensitivity, and AB-MR was significantly higher in specificity. Other indicators such as interval cancer rate or Breast Imaging Reporting \& Data System (BI-RADS) Category 3 rate did not show significant differences between the two groups. However, all studies are retrospective and there are no prospective data. Since the reported scores of AB-MRI and FP-MRI are comparable, it is difficult to test because the sample size is larger than 18,000 in order to perform a non-inferiority test on diagnostic scores. The purpose of this study was to compare the diagnostic results of secondary breast cancer surveillance using mammography, ultrasound, and MRI in a prospective multicenter study.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SCREENING
Masking
NONE
Enrollment
1,756
Comparison of diagnostic results of abbreviated breast MRI and full protocol MRI for secondary breast cancer surveillance
Inje University Busan Paik Hospital
Busan, BusanJin-Gu, South Korea
Samsung Medical center
Seoul, Gangnam-gu, South Korea
Soon Chun Hyang University Hospital Seoul
Seoul, Yongsan-Gu, South Korea
Cancer detection rate (CDR)
Comparison of cancer detection rate (CDR) between breast ultrasound and abbreviated magnetic resonance imaging (AB-MRI) or breast ultrasound and full protocol magnetic resonance imaging (FP-MRI)
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
Abnormal interpretation rate (AIR)
Comparison of abnormal interpretation rate in each test (mammography, ultrasound, abbreviated magnetic resonance imaging (AB-MRI), and full protocol magnetic resonance imaging (FP-MRI))
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
Sensitivity
Comparison of sensitivity of each test (mammography, ultrasound, abbreviated magnetic resonance imaging (AB-MRI), and full protocol magnetic resonance imaging (FP-MRI))
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
Specificity
Comparison of specificity of each test (mammography, ultrasound, abbreviated magnetic resonance imaging (AB-MRI), and full protocol magnetic resonance imaging (FP-MRI))
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
Positive predictive value
Comparison of positive predictive value of each test (mammography, ultrasound, abbreviated magnetic resonance imaging (AB-MRI), and full protocol magnetic resonance imaging (FP-MRI))
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Negative predictive value
Comparison of negative predictive value of each test (mammography, ultrasound, abbreviated magnetic resonance imaging (AB-MRI), and full protocol magnetic resonance imaging (FP-MRI))
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
Interval cancer rate
Interval cancer rate will be assessed for each test (mammography, ultrasound, abbreviated magnetic resonance imaging (AB-MRI), and full protocol magnetic resonance imaging (FP-MRI))
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
Invasive cancer detection rate
Comparison of invasive cancer detection rate between breast ultrasound and abbreviated magnetic resonance imaging (AB-MRI) or breast ultrasound and full protocol magnetic resonance imaging (FP-MRI)
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
Accuracy
Comparison of accuracy between breast ultrasound and abbreviated magnetic resonance imaging (AB-MRI) or breast ultrasound and full protocol magnetic resonance imaging (FP-MRI)
Time frame: The results of pathology tests or imaging or clinical follow-up tests 1 year after the 2nd round screening were used.
Patient reported outcomes (PRO) based on patient discomfort.
To compare patient reported outcome related to diagnostic testing with AB-MR and full-protocol MR based on patient discomfort. This dimension is rated on a 5-point scale from 1 (no problem) to 5 (extreme problems).
Time frame: Patient questionnaires will be collected at time points of clinic visits for study, assessed up to 3 months.
Patient reported outcomes (PRO) based on patient preference.
To compare patient reported outcome related to diagnostic testing with AB-MR and full-protocol MR based on patient preference. This dimension is rated on a 5-point scale from 1(AB-MR is twice as preferable as FP-MR) to 5(FP-MR is twice as preferable as AB-MR).
Time frame: Patient questionnaires will be collected at time points of clinic visits for study, assessed up to 3 months.