The goal of this clinical trial\] is to explore the clinical effect of laser acupuncture combined with Schroth training on adolescent idiopathic scoliosis (AIS) . The main question\[s\] it aims to answer are: * The effects of Schroth exercises on Cobb angles, angle of trunk rotation, spinal mobility, gait parameters and clinical efficacy in patients with AIS. * Laser acupuncture combined with Schroth method on Cobb angles, angle of trunk rotation, spinal mobility, gait parameters and clinical efficacy in patients with AIS. Participants will received Schroth exercise therapy and laser acupuncture therapy (MLS laser). If there is a comparison group: Researchers will compare received Schroth exercise therapy to see the effects of Schroth exercises and laser acupuncture combined with Schroth method on Cobb angles, angle of trunk rotation, spinal mobility, gait parameters and clinical efficacy in patients with AIS
In this study, the standard control, control group receipts schroth exercise therapy, while trial group receives Schroth exercise therapy and laser therapy. The design of the individual Schroth exercise is carried out according to the c urve patterns of the Schroth classification. The Schroth classification criteria includes four curve patterns that are determined with reference to the location of the curves, the importance of lumbar and thoracic prominences, and the effect of the scoliosis on the pelvis. Laser therapy was performed w ith a dual wavelength, high power IR laser (Multiwave Locked System (MLS®) laser, Mphi, ASA srl, Vicenza, Italy) and the laser acupuncture points include DU2, GB30, DU9, SP6, LR8, DU6, DU4, DU12. Laser puncture acupuncture points had been identified according to Traditional Chinese Medicine (TCM) and treated with handpiece optical group following the detailed treatment parameters: 900Hz, FPW mode, 60 s per point, 29.12J, spot size 3 cm2, energy density 27J/cm2. All treatments are performed five times in a week for 4 consecutive weeks.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
80
The Schroth classification criteria includes four curve patterns that are determined with reference to the location of the curves, the importance of lumbar and thoracic prominences, and the effect of the scoliosis on the pelvis.
Laser therapy was performed w ith a dual wavelength, high power IR laser (Multiwave Locked System (MLS®) laser, Mphi, ASA srl, Vicenza, Italy) and the laser acupuncture points include DU2, GB30, DU9, SP6, LR8, DU6, DU4, DU12. Laser puncture acupuncture points had been identified according to Traditional Chinese Medicine (TCM) and treated with handpiece optical group following the detailed treatment parameters: 900Hz, FPW mode, 60 s per point, 29.12J, spot size 3 cm2, energy density 27J/cm2. All treatments are performed five times in a week for 4 consecutive weeks.
Dalian Second People's Hospital
Dalian, China
Cobb angle(°)
Draw a line through the spine on the upper surface of the upper vertebra and the lower surface of the lower vertebra on the X-ray film, and make the vertical line of the above two lines, and measure the angle between the two vertical lines. All radiographs are measured three times by a professional physician with the same protractor, and the average value is recorded
Time frame: before the whole treatment cycle
Cobb angle(°)
Draw a line through the spine on the upper surface of the upper vertebra and the lower surface of the lower vertebra on the X-ray film, and make the vertical line of the above two lines, and measure the angle between the two vertical lines. All radiographs are measured three times by a professional physician with the same protractor, and the average value is recorded
Time frame: 6 months after treatment
Cobb angle(°)
Draw a line through the spine on the upper surface of the upper vertebra and the lower surface of the lower vertebra on the X-ray film, and make the vertical line of the above two lines, and measure the angle between the two vertical lines. All radiographs are measured three times by a professional physician with the same protractor, and the average value is recorded
Time frame: 12 months after treatment
Trunk rotation angle(°)
Trunk rotation angle (ATR) is measured with scoliosis instrument to quantitatively evaluate the chest rotation angle and waist rotation angle.
Time frame: before the whole treatment cycle
Trunk rotation angle(°)
Trunk rotation angle (ATR) is measured with scoliosis instrument to quantitatively evaluate the chest rotation angle and waist rotation angle.
Time frame: 6 months after treatment
Trunk rotation angle(°)
Trunk rotation angle (ATR) is measured with scoliosis instrument to quantitatively evaluate the chest rotation angle and waist rotation angle.
Time frame: 12 months after treatment
Musculoskeletal stiffness
Use PulStarG3 system (Sense Technology Inc) to evaluate the musculoskeletal stiffness of each spinal segment. The handheld pulse head presses on the patient and provides a single low-energy pulse to the vertebral layer of interest. The force sensor in the pulse head measures the resistance to the pulse and transmits the analysis results to a digital computer, which can be considered as a computer-assisted spinal palpation in a series of bar graphs (abnormal musculoskeletal hardness is shown in the red bar and normal musculoskeletal hardness is shown in the green bar).
Time frame: before the whole treatment cycle
Musculoskeletal stiffness
Use PulStarG3 system (Sense Technology Inc) to evaluate the musculoskeletal stiffness of each spinal segment. The handheld pulse head presses on the patient and provides a single low-energy pulse to the vertebral layer of interest. The force sensor in the pulse head measures the resistance to the pulse and transmits the analysis results to a digital computer, which can be considered as a computer-assisted spinal palpation in a series of bar graphs (abnormal musculoskeletal hardness is shown in the red bar and normal musculoskeletal hardness is shown in the green bar).
Time frame: 6 months after treatment
Musculoskeletal stiffness
Use PulStarG3 system (Sense Technology Inc) to evaluate the musculoskeletal stiffness of each spinal segment. The handheld pulse head presses on the patient and provides a single low-energy pulse to the vertebral layer of interest. The force sensor in the pulse head measures the resistance to the pulse and transmits the analysis results to a digital computer, which can be considered as a computer-assisted spinal palpation in a series of bar graphs (abnormal musculoskeletal hardness is shown in the red bar and normal musculoskeletal hardness is shown in the green bar).
Time frame: 12 months after treatment
Gait(stride length (m))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: before the whole treatment cycle
Gait(stride time(s))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: before the whole treatment cycle
Gait(walking speed(m/s))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: before the whole treatment cycle
Gait(stride length (m))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: 6 months after treatment
Gait(stride time(s))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: 6 months after treatment
Gait(walking speed(m/s))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: 6 months after treatment
Gait(stride length (m))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: 12 months after treatment
Gait(stride time(s))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: 12 months after treatment
Gait(walking speed(m/s))
collected by wearable devices (micro-electro-mechanical systems, MEMS), the sampling frequency is set at 20 Hz, and transmitted to the computer server according to the manufacturer's protocol. The collected gait parameters include average pressure distribution, stride length, stride length and walking speed.
Time frame: 12 months after treatment
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.