This study was conducted to radiographically evaluate peri-implant and alveolar bone height changes of locator attachments used for three implant assisted mandibular complete overdenture using two different pick up protocols.
This clinical trial was done to evaluate the effect of using block-out spacer during picking up of locator attachments used for retaining 3 implant mandibular complete overdenture regarding peri-implant and alveolar bone height changes. Eighteen egyptian completely edentulous male patients were chosen from the Outpatient Clinic of the Prosthodontics Department, Faculty of Dentistry, Mansoura University, Egypt. Patients received three implants one anterior in midline area and two posterior at first molar area . Patients free from any systemic diseases relating to the bone resorption, not taking any drugs that interfere with bone quality .Patients with absolute contraindication for surgical implantation, general contraindication , relative contraindication ,local contraindication for surgical implantation , allergic reactions to titanium or to local anesthesia were excluded. The main question it aims to answer is whether to use block-out spacer during picking up of locator attachments used for retaining 3 implant mandibular complete overdenture or not. * Participants were given antibiotic prophylaxis (clavulanic acid with amoxicillin 1 gm twice/day) one hour prior to surgery and continued for 6-7 days postoperative .Also, 50 mg of non-steroid anti-inflammatory tablets and analgesic (Declophenac tab) were given twice daily for one week after surgery. In addition to, Antiseptic mouth wash (0.2% chlorohexidine) was started ten minutes before surgery and continued one week after surgery twice daily. * Patients were asked for radiographic evaluation immediately (T0) and 6 (T6) then 12 months (T12) after picking up of locator attachments. Researcher compared between Block out spacer group (BOS-G) and Without block out spacer group (WBOS-G)which were randomly assigned into two equal groups to see if using block out spacer during picking up of locator attachments used for retaining 3 implant mandibular complete overdenture is more beneficial regarding peri-implant and alveolar bone height changes or not.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
18
Three dental implants were placed (one anterior in midline area and two posterior at first molar area).
Implants were loaded after three months by using locator attachments. Control group:Iocator attachments picked up using block out spacer. Study group:Iocator attachments picked up without using block out spacer
Rahma El Hussany
Al Mansurah, Egypt
Peri-implant bone height changes (bone loss)
Evaluations of vertical and horizontal peri-implant bone loss in mm by digital periapical radiography.
Time frame: one year.
Residual alveolar bone height changes (bone loss)
Evaluations of vertical residual alveolar bone loss in mm by panoramic radiography.
Time frame: one year.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.