The objective of ILAN is to assess the safety, feasibility and bronchodilator efficacy of in-line bronchodilator nebulizer delivery with VMN via HFNC system in hypoxemic respiratory failure patients treated with bronchodilators and compare this method to standard-nebulization using a jet nebulizer with a facial mask. The investigators hypothesized that aerosol nebulization using HFNC/VMN represents safer and more convenient approach in hypoxemic respiratory failure patients in comparison to conventional therapy while providing similar bronchodilator efficacy.
Objective: To evaluate the safety and feasibility of a novel approach to nebulization treatment via the nasal route in patients with severe hypoxemic respiratory failure dependent on high flow oxygen. Hypothesis: In-line vibrating mesh nebulizer delivery via HFNC systems is a safe, feasible and efficacious approach in comparison to traditional jet nebulizer delivered nebulization in hypoxemic respiratory failure patients whose usual care includes nebulized drugs. Specific Aims: 1. To evaluate the safety and feasibility of administering vibrating mesh nebulizer-delivered therapy in patients with acute hypoxemic respiratory failure requiring high flow nasal cannula. 2. To evaluate the effect of trans-nasal nebulization on patient comfort and satisfaction with therapy in comparison with standard jet nebulization. 3. To evaluate differences in resource utilization between patients receiving standard jet nebulization and ILAN with HF, including time spent at the bedside by the respiratory therapist (RT) for delivery of the medication and any additional time gathering setting up and cleaning. 4. To evaluate patient and therapist perceptions and preference on the various delivery methods of aerosol delivery. Study Design: ILAN is a double-crossover, multi-center trial evaluating the safety and feasibility of in line nebulized medication with high flow nasal canula in comparison to standard jet nebulizer therapy in acute respiratory failure requiring the utilization of high flow nasal cannula. Intervention: Enrolled patients will receive two standard forms of inhaled medications as ordered by the physician. Patients will be randomized into two paths of the cross over study. There will be no blinding involved in this randomization. Path A will have medications delivered trans-nasally in line via the vibrating mesh nebulizer (VMN) with the high flow nasal cannula followed by standard jet nebulization (SJN) with face mask at the next time of medication dosing 3-6 hours later. Path B will receive standard jet nebulization without HFNC followed by the trans-nasal in line nebulization via the HFNC. Patients selected to enroll in day 2 of the trial will have their clinical path alternated in attempt to control for diurnal variability. All patients will also receive as-needed nebulized treatments as well as usual supportive care provided by respiratory therapists. As needed therapy will be delivered via the method of the current arm of the study they are in, and the washout period will subsequently reset.
nebulized delivery of bronchodilator via in-line drug delivery maintaining high-flow nasal cannula oxygen
standard jet nebulization delivery of bronchodilator
Ronald Reagan Medical Center at UCLA
Los Angeles, California, United States
Santa Monica UCLA
Santa Monica, California, United States
Maximal decrease in SpO2 during nebulization with jet nebulizer vs. inline via HFNC compared to the baseline SpO2 values prior to the nebulization therapy
Primary Outcome
Time frame: up to 48 hours
Proportion of patients with documented hypoxemia (<88%) during the nebulization
Safety Outcome
Time frame: up to 48 hours
Duration of hypoxemic episodes with SpO2<88% during the nebulization delivery
Safety Outcome
Time frame: up to 48 hours
Lowest absolute desaturation from the beginning until completion of nebulizer treatment compared to the baseline SpO2 values defined as the lowest adequately measured SpO2 within two minutes prior to the nebulization
Safety Outcome
Time frame: up to 48 hours
Increase in respiratory rate from the baseline during the nebulization by >10%
Safety Outcome
Time frame: up to 48 hours
Change in respiratory rate during nebulization compared to the baseline rate
Safety Outcome
Time frame: up to 48 hours
Requirement for additional interventions to maintain patient's safety during the nebulization
Safety Outcome: (Increased O2 flow (yes/know and rate increase) or increased O2 FiO2 (yes/know and rate increase) )
Time frame: up to 48 hours
Need to increase O2 support after the nebulization therapy to maintain SpO2>88%
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
NONE
Enrollment
40
Safety Outcome
Time frame: up to 48 hours
Nosebleed within 2 hours of nebulizer delivery
Safety Outcome
Time frame: up to 48 hours
ROX score
Safety Outcome (While not externally validated, the ROX Index is a simple bedside calculation using three clinical variables and is one easy way to summarize a patient's degree of hypoxemic respiratory failure - gives risk of intubation - low to high)
Time frame: up to 48 hours