Assessing the response to vascular filling in shock is a challenge in emergency medicine. The mitral annulus velocity measured by tissue Doppler (E') has recently been characterized as sensitive to the preload conditions of a patient. The investigators hypothesize that the E' variation (∆E') before and after fluid filling allows us to assess the response to vascular filling. The investigators hypothesize that the ∆E' has a good diagnostic performance to establish whether a patient is responsive to fluid filling, defined by an area under the ROC curve greater than 0.75.
Assessing the response to vascular filling in shock is a challenge in emergency medicine. Trans thoracic ultrasound (TTS) is recommended for the diagnosis and management of this type of patient. TTS allows real-time monitoring of the effectiveness of a therapeutic . In case of circulatory failure without cardiac failure, it is recommended to perform fluid filling tests based on an increase in of indicators to assess preload dependence. The change in subaortic VTI, which has become the gold standard in clinical practice for diagnosing fluid filling response, suffers from a lack of technical feasibility. The mitral annulus velocity measured by tissue Doppler (E') has recently been characterized as sensitive to the preload conditions of a patient. The high feasibility of this technique makes its study interesting for the evaluation of the preload (and its variation after variation after vascular filling) of the patient in shock in the emergency department. To our knowledge, there are no clinical studies exploring the relevance of this technique to evaluate fluid filling response in patient admitted with shock in the emergency department. The investigators hypothesize that the E' variation (∆E') before and after fluid filling allows us to assess the response to vascular filling. The investigators hypothesize that the ∆E' has a good diagnostic performance to establish whether a patient is responsive to fluid filling, defined by an area under the ROC curve greater than 0.75. The main objective of this study is to investigate the diagnostic performance of ∆E' in establishing response to fluid filling in a prospective cohort of patients admitted to the emergency department with shock requiring vascular filling.
Study Type
OBSERVATIONAL
Enrollment
187
During the inclusion visit, the patient will receive 3 cardiac ultrasonography. The first one will be performed at the time of the initiation of the 500mL vascular filling (T0), without delaying and the second one after the end of the filling (Tfin). These first two ultrasound are part of standard practice. A third will be performed 20 minutes after the end of the vascular filling (Tfin+20).
CHU de Nîmes
Nîmes, France
RECRUITINGE' variation (∆E')
The E' wave will be measured by tissue Doppler at the initiation (T0) of the filling and after the end of the vascular (Tfin) to determine its variation (%) between these two times of measurement.
Time frame: Inclusion time
Fluid filling responsiveness
Vascular filling is defined by the intravenous administration of 500 mL of crystalloid for 20 to 30 minutes, decided by the physician in charge. The response to filling will be evaluated by the variation of the time velocity index between T0 and Tfin (∆ITV) measured with pulsed Doppler. Patients will be considered : * Responder (R) group if ∆ITV ≥ 15% * Nonresponder group (NR) if ∆ITV \< 15%.
Time frame: Inclusion time
∆E'late
∆E'late: the E' wave will be measured by trans thoracic ultrasound before vascular filling (T0) and 20 minutes after the end of vascular filling (Tfin+20) to determine its variation (%) between these two times of measurement.
Time frame: Inclusion time
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.