The goal of this study is to investigate the effectiveness of stand-alone air filtration for improving indoor air quality (IAQ) and chronic obstructive pulmonary disease (COPD) outcomes in a high-risk urban cohort of 80 U.S. military veterans with COPD. Secondary goals of the study are to (1) investigate housing-related factors that may contribute to COPD exacerbation, (2) investigate the utility of using low-cost sensors for indoor air pollution epidemiology studies and for providing actionable or useful information on the quality of their indoor air to patients and their physicians, and (3) evaluate the costs and benefits of using stand-alone air filtration to improve IAQ and COPD outcomes.
The study will utilize a randomized, single-blind, placebo-controlled case-control design in which stand-alone portable air cleaners will be introduced to the study population over a period of approximately 1 year. One-half of the study population (40 participants) will receive a normally functioning filtration unit (i.e., an air cleaner with HEPA filter installed) and one-half of the study population (40 participants) will receive a placebo filtration unit (i.e., an air cleaner with the primary filter removed). The participants will be blinded; they will not know the status of the filter. Stand-alone portable air cleaning units containing HEPA filters and high clean air delivery rates (CADRs) sufficiently sized for the spaces they will serve will be used. The study will also involve housing condition assessments conducted in each home to characterize housing-related factors that may contribute to COPD exacerbation at baseline, as well as measurements of indoor and outdoor air quality and environmental conditions, and records of clinical outcomes (e.g., COPD exacerbations, emergency room visits, 6-minute walk distance, oxygen saturation, etc. accessed through the subject's VA medical record) throughout the study duration. The validated and extensively used St. George's Respiratory Questionnaire (SGRQ-C) and Veterans RAND 36-Item Health Survey (VR-36) will be used to determine health-related quality of life (HR-QoL) of participants by the JBVAMC Study Personnel. Clinical outcomes will also be used to assess costs of care with and without filtration interventions in this population. Low-cost air quality sensors will be used to monitor IAQ for the duration of the study). The study will also evaluate the upfront costs and operational and maintenance costs of the air cleaners over the course of the intervention periods and will compare them to the expected impacts on costs of care both with and without filtration interventions in this population.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
80
Austin Air Healthmate air cleaner with or without standard filter
Jesse Brown Veterans Affairs Medical Center
Chicago, Illinois, United States
COPD exacerbations
Physician diagnosed exacerbation of acute COPD
Time frame: Through study completion, an average of 1 year
ED visits
Number of emergency room visits
Time frame: Through study completion, an average of 1 year
Urgent care visits
Number of urgent care visits
Time frame: Through study completion, an average of 1 year
Unscheduled clinic visits
Number of unscheduled clinic visits
Time frame: Through study completion, an average of 1 year
6MWD
6-minute walk distance
Time frame: At the end of study completion, an average of 1 year
O2 sat
Transcutaneous oxygen saturation at rest and during 6MWD
Time frame: At the end of study completion, an average of 1 year
Health related quality of life
Veterans Rand 36 Item Healthy Survey (VR 36)
Time frame: At the end of study completion, an average of 1 year
St. George's
St. George's Respiratory Questionnaire (SGRQ) score
Time frame: At the end of study completion, an average of 1 year
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.