Background: The choice whether or not to preserve the posterior cruciate ligament (PCL) in total knee arthroplasty (TKA) is coupled to the us of a PCL-retaining (CR) or a condylar (CS) insert. The CS insert is anterior-lipped (AL) to prevent anterior translation of the femur on the tibia with flexion and compensate the function of the PCL. Currently both the CR and CS insert are made of highly cross-linked polyethylene (HXPLE) to theoretically reduce wear related osteolysis. However, this also might diminish the fracture toughness and crack propagation of the insert. The investigators expect that due to the high contact forces on the anterior lip of the CS insert during flexion, especially in younger and more active patients, and the lower fracture toughness of HXPLE, the CS insert insert might show more migration, wear or other damage compared to the CR insert in the long-term, which might lead to more revisions in the CS insert compared to the CR insert. To measure the migration and wear, during surgery tantalum markers will be inserted in the host bone using a marker inserter. The displacement of the prosthesis with reference to the host bone will be measured using model-based RSA. Both tantalum markers ande the inserter are already used for study purposes. However, the safety and usability are not registered before. Objective: The primary objective is to compare the migration of both the femoral and tibial component by the use of a CS insert or CR insert both made of HXPLE using model-based roentgen stereophotogrammetric analysis (mRSA). Furthermore, the safety and usability of the tantalum markers and the marker inserter will be determined. The secondary objective is to determine the influence of the type of insert on the wear, inducible displacement, survival and clinical outcomes. Study design: A randomized controlled trial Study population: Forty-four patients scheduled to undergo primary total knee replacement, aged below 70 years with an ASA-score of 1 or 2 will be needed in total, divided in two groups of 22 patients each. Intervention: One group receives an uncemented TKP with a CS insert, while the other group receives an uncemented TKP with a CR insert. Both will be placed using the MAKO-robotic arm using a kinematic balancing technique. Outcomes: Main study parameters are migration of the femoral and tibial components measured with model-based RSA software till 10 years postoperatively. Furthermore, the stability of the markers will be determined and the complications due to the markers and/or the marker inserter will be registered. The secondary parameters are wear, inducible displacement, survival, clinical outcomes and complications up to 10 years postoperatively.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
Enrollment
44
During TKA surgery a Condylar Stabilizing (CS) insert is implanted and tantalum beads are placed around the prosthesis.
During TKA surgery a Cruciate Retaining (CR) insert is implanted and tantalum beads are placed around the prosthesis.
Reinier Haga Orthopedisch Centrum
Zoetermeer, South Holland, Netherlands
RECRUITINGTranslations (mm)
The translations of the femoral and tibial components measured in 3 axis (z, y and z) with model-based RSA over 10 years.
Time frame: 10 years after surgery
Rotations (degrees)
The rotations of the femoral and tibial components measured in 3 axis (z, y and z) with model-based RSA over 10 years.
Time frame: 10 years after surgery
Stability of the tantalum markers
Stability of the tantalum markers will be determined by the mean error value of the markers.
Time frame: 10 years after surgery
Safety of the tantalum markers and the inserter
Safety of the tantalum markers are determined by registration of the complications due to the markers and/or marker inserter. Complications will be expressed by numbers and percentages.
Time frame: 10 years after surgery
Wear
Wear of the insert measures in 3 axis (x, y and z)
Time frame: 10 years after surgery
Inducible displacement (mm)
The inducible displacement gives insight into the nature and durability of the fixation and is defined as the micromotion occurring in response to external forces. The inducible displacement will be expressed by translations (x-, y- and z-direction) in mm
Time frame: 10 years after surgery
Inducible displacement (degrees)
The inducible displacement gives insight into the nature and durability of the fixation and is defined as the micromotion occurring in response to external forces. The inducible displacement will be expressed by rotations (x-, y- and z-direction) in degrees.
Time frame: 10 years after surgery
Survival
Survival of the CS and CR inserts is measured by registration of all complications and is expressed by numbers and percentages.
Time frame: 10 years after surgery
Clinical outcomes: Knee Society Score (KSS)
The Knee Society Score (KSS) is a questionnaire to rate the knee prosthesis function. A high score means a good function and a low score means a worse function. The score varies between 0 and 100.
Time frame: 10 years after surgery
Clinical outcomes: Numeric Rating Scale for pain (NRS pain)
The Numeric Pain Rating Scale (NRS) measures the amount of pain experienced in the past week during rest and activity. It is a scale from 0 (no pain) to 10 (worst pain imaginable)
Time frame: 10 years after surgery
Clinical outcomes: EuroQol 5D (EQ-5D-5L)
The EuroQol-5D-5L (EQ-5D-5L) is a questionnaire that describes the overall health condition of the person. The score is given by an index consisting of 5 numbers, which represents a health status. A lower score indicates a good condition. The last question of this questionnaire is the overall health condition of the person on a scale of 0 to 100. In this question a higher score indicates a good condition.
Time frame: 10 years after surgery
Clinical outcomes: Knee Injury and Osteoarthritis Outcome Score (short version, KOOS-PS)
The Knee Injury and Osteoarthritis Outcome Score - short version (KOOS-PS) is a questionnaire about the ability to perform normal daily activities. A high score means that the activities cost a lot of effort to perform, while a low score means that the activities can be done with minimum effort. The score varies between 0 and 100.
Time frame: 10 years after surgery
Clinical outcomes: Forgotten Joint Score (FJS)
The Forgotten Joint score (FJS) is a questionnaire about the awareness of the prosthetic knee. A high score means a low awareness and a low score means a high awareness. The score varies between 0 and 100.
Time frame: 10 years after surgery
Clinical outcomes: Numeric Rating Scale for Satisfaction (NRS satisfaction)
The satisfaction is a single question about the overall satisfaction of the result of the surgery on a scale from 0 (very unsatisfied) to 10 (very satisfied).
Time frame: 10 years after surgery
Clinical outcomes: Oxford Knee Score (OKS)
The Oxford Knee Score (OKS) is a questionnaire about the amount of influence of the operated knee on the persons life. A low score means that the life of the person is influenced a lot by the operated knee, while a high score means that the life of the persons is little influenced by the operated knee. The score varies between 0 and 48.
Time frame: 10 years after surgery
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.