The presence of solid food or fluid residue in the stomach is always a major concern when patients require medical procedures under sedation or general anesthesia, due to the high risk of pulmonary aspiration of the stomach contents. This is especially important in emergency procedures, when a fasting period could not be observed. Pulmonary aspiration of gastric content is a serious perioperative complication of obstetric anesthesia, and it is associated with morbidity and mortality. Information from a bedside ultrasound assessment of the stomach may be a very useful resource to decide whether it's safe to proceed, cancel or delay a surgical procedure. The ultrasound assessment of the stomach content has shown to be very feasible and practical in non-pregnant patients. However, it has not been determined whether the competence reached by anesthesiologists in non-pregnant subjects can be transferred to the obstetric population, especially in term pregnant patients where it could be difficult to identify the stomach because of the presence of the gravid uterus. Although quantitative assessment of the gastric antrum cross-sectional area in terms of intra- and interrater reliability has been evaluated in non-pregnant adults, it remains to be evaluated in pregnant patients. Furthermore, it has not been determined whether the performance of novice operators is comparable to expert operators in the gastric quantitative assessment. This study aims to determine whether trained anesthesiologists can reliably assess the stomach content of pregnant patients by ultrasound, evaluating the inter- and intra-rater reliability of quantitative gastric ultrasound in term pregnant patients comparing anesthesiologists of different level of expertise. The investigators hypothesize a substantial to almost perfect agreement in the intra- and interrater reliability of the antral cross-sectional area among raters in term pregnant patients scheduled for elective cesarean delivery.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
30
The gastric antrum will be scanned using ultrasound.
Mount Sinai Hospital
Toronto, Ontario, Canada
Antral cross-sectional area (supine position)
The cross-sectional area (in centimeters squared) of the antrum will be measured with the patient in supine position, using the ultrasound machine. Measurements will be done 3 times, by 2 investigators.
Time frame: 5 minutes
Antral cross-sectional area (right lateral decubitus)
The cross-sectional area (in centimeters squared) of the antrum will be measured with the patient in right lateral decubitus position, using the ultrasound machine. Measurements will be done 3 times, by 2 investigators.
Time frame: 5 minutes
Intra-rater reliability calculation
Intra-rater reliability will be calculated using the 3 measurements, for each rater.
Time frame: 5 minutes
Inter-rater reliability calculation
Inter-rater reliability will be calculated using the 3 measurements, between raters.
Time frame: 5 minutes
Grading of stomach contents
Grading scale: grade 0 means no gastric contents are visualized in supine and the right lateral decubitus, grade 1 means gastric contents are visualized in right lateral decubitus but not in supine decubitus, and grade 2 means gastric contents are visualized in both positions
Time frame: 5 minutes
Gastric volume (supine position)
Gastric volume (ml) will be estimated using the antral cross-sectional area obtained with the patient in supine position
Time frame: 5 minutes
Gastric volume (right lateral decubitus)
Gastric volume (ml) will be estimated using the antral cross-sectional area obtained with the patient in right lateral decubitus.
Time frame: 5 minutes
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.