More than 10% of the US population have obstructive sleep apnea (OSA). Standard of care is therapy with CPAP (continuous positive airway pressure) which virtually eliminates OSA. However, most patients use CPAP only for part of the night (4-5hours) and about 50% patients discontinue CPAP long-term. Alternative therapies are limited, thus many OSA patients remain at risk of OSA sequelae (e.g. sleepiness, memory issues, high blood pressure, etc.). Importantly, different patients get OSA for different reasons, and recent data show that some of the underlying causes of OSA ("endotypes") such as having a low arousal threshold (i.e. waking up easily) are associated with lower CPAP adherence. Using a randomized controlled trial design, this will be the first study using a targeted intervention to manipulate the underlying OSA causes (i.e., giving a safe hypnotic to patients with OSA to increase the arousal threshold) to test the hypothesis that endotype-targeted therapy increases CPAP-adherence in patients who have low but continued CPAP usage. Ultimately, this strategy may improve the care and outcomes of millions of undertreated OSA patients.
This double-blind, randomized, placebo-controlled, single-center, phase II trial, will test if endotype-targeted drug therapy increases CPAP adherence. Patients with low CPAP adherence (i.e. CPAP use 0.5-4h/night) will be randomized in parallel to CPAP+Eszopiclone vs CPAP+Placebo for 2 weeks. The primary outcome is mean TimeOnCPAP/night on days 2-14 after initiation of study drugs. Aim 1: To test the effect of eszopiclone on CPAP usage in unselected OSA patients with low CPAP adherence. Hypothesis 1: Eszopiclone improves CPAP usage more than placebo. Aim 2: To test the effect of eszopiclone on CPAP usage in OSA patients with a low vs a high arousal threshold (ArTH) endotype. Hypothesis 2: Eszopiclone improves CPAP usage substantially more in OSA patients with a low vs a high ArTH. Further, this study will explore the mechanisms through which eszopiclone may affect CPAP usage, the effect of eszopiclone on underlying sleep apnea severity, and if the intervention and its potential effects on adherence translate into changes in clinically important outcomes (i.e., vigilance and sleepiness).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
QUADRUPLE
Enrollment
42
Eszopiclone tablet (encapsulated)
Sugar capsule manufactured to match encapsulated Eszopiclone
UC San Diego; Altman Clinical and Translational Research Institute Building
La Jolla, California, United States
Mean use per night of continuous positive airway pressure (CPAP)
Based on device recorded usage
Time frame: days 2-14 after initiation of study drugs
Alternative measures of CPAP usage
E.g. percentage of nights with CPAP \>4h
Time frame: days 2-14 after initiation of study drugs
Response Speed
Based on 10-minute Psychomotor vigilance task (PVT)
Time frame: days 2-14 after initiation of study drugs
Patient-Reported Outcomes Measurement Information System (PROMIS) Sleep Disturbance (SDA) instrument
Based on response pattern scoring, the PROMIS 8-item SDA score will be converted into a T-score with a mean of 50 (reflecting the average for the United States general population) and a standard deviation of 10. Higher t-scores reflect greater sleep disturbance.
Time frame: days 2-14 after initiation of study drugs
Patient-Reported Outcomes Measurement Information System (PROMIS) Sleep-Related Impairment (SRI) instrument
Based on response pattern scoring, the PROMIS 8-item SRI score will be converted into a T-score with a mean of 50 (reflecting the average for the United States general population) and a standard deviation of 10. Higher t-scores reflect greater sleep-related impairment.
Time frame: days 2-14 after initiation of study drugs
Patient-Reported Outcomes Measurement Information System (PROMIS) Fatigue instrument
Based on response pattern scoring, the PROMIS 8-item Fatigue score will be converted into a T-score with a mean of 50 (reflecting the average for the United States general population) and a standard deviation of 10. Higher t-scores reflect greater sleep-related impairment.
Time frame: days 2-14 after initiation of study drugs
Epworth Sleepiness Scale (ESS)
The ESS is an 8-item instrument assessing the likelihood of dozing off in 8 different situations with points for each item ranging from 0 to 3 (0 = would never doze off; 3 = high chance of dozing off). The points for each item are summed up, thus the total score ranges from 0 to 24, with higher ESS scores indicating greater sleepiness.
Time frame: days 2-14 after initiation of study drugs
Apnea Hypopnea Index
The AHI is a measure of sleep apnea severity and is defined as the number of apneas and hypopneas per hour of sleep.
Time frame: day1 of study drugs
Mean Blood Pressure (mmHg)
Average of two in-office blood pressure measurements
Time frame: day 14 after initiation of study drugs
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.