shoulder sub acromial impingement syndrome is an encroachment of subacrormial tissues, rotator cuff, subacrormial bursa, and the long head of the biceps tendon, as a result of narrowing of the subacrormial space. Activities requiring repetitive or sustained use of the arms over head often predispose the rotator cuff tendon to injury. Hence the objective of the study is to examine the influence of extra corporeal Shock wave versus phonophoresis on pain severity and functional disability in patients with sub acromial impingement syndrome.
Background: shoulder sub acromial impingement syndrome is an encroachment of subacrormial tissues, rotator cuff, subacrormial bursa, and the long head of the biceps tendon, as a result of narrowing of the subacrormial space. Activities requiring repetitive or sustained use of the arms over head often predispose the rotator cuff tendon to injury. Objective of the study: To examine the influence of extra corporeal Shock wave versus phonophoresis on pain severity and functional disability in patients with sub acromial impingement syndrome. Subjects and Methods: Thirty patients diagnosed as shoulder impingement syndrome stage II Neer classification due to mechanical causes. Patients were randomly distributed into two equal groups. The first group consisted of 15 patients with a mean age of 45.46 (+ 8.64) received therapeutic exercises( stretching exercise of posterior shoulder capsule and strengthening exercises of shoulder muscles) and shockwave therapy (6000 shock, 2000/session, 3 sessions, 2 weeks a part, 0.22mJ/mm2) years. The second group consisted of 15 patients with a mean age of 46.26 (+ 8.05) received same therapeutic exercises and phonophoresis (3 times per week, each other day, for 4 consecutive weeks). Patients were evaluated pretreatment and post treatment for shoulder pain severity, shoulder functional disability, shoulder flexion, abduction and internal rotation motions.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Radial extracorporeal shock wave device, it is serial number (1107394), medispec and connected to electrical supply 115/220 A C frequency.
Pagani ultrasound apparatus 200 cosistts of multi frequency head(1 and 3 MHz), surface area 4 cm², continuous and pulsed mode, main voltages: 100-240-VAC.50/60Hz.
Dr. Gopal Nambi
Al Kharj, Riyadh Region, Saudi Arabia
Pain intensity
Pain assessed by (Visual analog scale (VAS). VAS is a scale that allows continuous data analysis and uses a 10cm line with 0 (no pain) and 10 (worst pain) on the other end .Patients were asked to place a mark a long the line to denote their level of pain.
Time frame: Baseline
Pain intensity
Pain assessed by (Visual analog scale (VAS). VAS is a scale that allows continuous data analysis and uses a 10cm line with 0 (no pain) and 10 (worst pain) on the other end .Patients were asked to place a mark a long the line to denote their level of pain.
Time frame: 6 weeks
Functional disability
It was assessed by using the shoulder pain and disability index (SPADI) which is a valid and reliable index for measuring shoulder pain and disability. It consists of two parts, part one which assesses pain and part two which assesses functional disability. Scores were calculated as follow, in part one pain scores in all questions were added, and the mean value was chosen. In part two functional score of all questions were added and the mean value was chosen for the purpose of data analysis. Final score for each part was statistically analyzed separately.
Time frame: Baseline
Functional disability
It was assessed by using the shoulder pain and disability index (SPADI) which is a valid and reliable index for measuring shoulder pain and disability. It consists of two parts, part one which assesses pain and part two which assesses functional disability. Scores were calculated as follow, in part one pain scores in all questions were added, and the mean value was chosen. In part two functional score of all questions were added and the mean value was chosen for the purpose of data analysis. Final score for each part was statistically analyzed separately.
Time frame: 6 weeks
Range of motion
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Enrollment
30
In this study the shoulder flexion, abduction and internal rotation were measured by using(Model 01129 Guymon goniometer). It is an electrogoniometer which eliminates the need of manually score each measurement by storing the information internally, it reduces time. It measure any joint angle quickly and accurately. It has range of 0 to 360 and stores up to 80 data points. The validity and reliability of electrogoniometer for shoulder assessment was tested and well documented.
Time frame: Baseline
Range of motion
In this study the shoulder flexion, abduction and internal rotation were measured by using(Model 01129 Guymon goniometer). It is an electrogoniometer which eliminates the need of manually score each measurement by storing the information internally, it reduces time. It measure any joint angle quickly and accurately. It has range of 0 to 360 and stores up to 80 data points. The validity and reliability of electrogoniometer for shoulder assessment was tested and well documented.
Time frame: 6 weeks