The primary research objective is to determine the safety, feasibility, usability and validity of textile-enabled monitoring systems designed to capture physiologic variables, or "biological signals," related to cardiopulmonary function in children through comparison to hospital-based, standard-of-care monitoring in the Sickkids Cardiac Critical Care Unit (CCCU).
This single-arm, non-randomized study is a usability, technology feasibility and data correlation study which will employ a convenience sampling method. The study will compare the quality of data obtained by the Myant Inc Skiin Pediatric Band smart textile device to the gold-standard data generated by the clinical devices in the CCCU at SickKids. The primary research objective is to determine the safety, feasibility, usability and validity of textile-enabled monitoring systems designed to capture physiologic variables, or "biological signals," related to cardiopulmonary function in children through comparison to hospital-based, standard-of-care monitoring in the SickKids CCCU. The secondary objectives are as follows; (1) To design textiles for infants and children that allow safe, developmentally appropriate care, (2) To investigate the optimum placement of biosensors to measure physiologic parameters such as heart and respiratory rate within the textile-based approach, (3) To validate the textile-based approach, including the integrated sensors, through comparison to physiologic data gathered as part of routine patient care through traditional comparative analysis, (4) To investigate usability of the textiles, including placement, removal, and effects on patient care activities, and (5) To gather clinician feedback on the textile use and design.
Study Type
OBSERVATIONAL
Enrollment
100
Infants that meet the inclusion criteria will be equipped with a Skiin pediatric band appropriate for their chest size. Heart rate, respiratory rate, temperature, and electrocardiogram will be monitored from 2 to 12 hours through the Skiin pediatric band and a standard of care device (Phillips Intellivue MX750) commonly used in the CCCU at SickKids.
The Hospital for Sick Children (SickKids)
Toronto, Ontario, Canada
RECRUITINGHeart Rate
The difference between heart rate measured from Skiin data and from standard of care device.
Time frame: collection during the single study session of 2-12 hours.
Respiratory Rate
The difference between respiratory rate measured from Skiin data and from standard of care device.
Time frame: collection during the single study session of 2-12 hours.
Temperature
The difference between temperature measured from Skiin data and from standard of care device.
Time frame: collection during the single study session of 2-12 hours.