" Hepatic artery variants are occasionally seen, especially 20-30% of aberrant left hepatic artery. In radical gastrectomy, decision for aberrant left hepatic artery(ALHA) ligation should consider the oncologic safety and liver-related complication. Theoretically, the ALHA preservation is the most ideal in the aspect of liver function protection. However, it is technically difficult which consumes much time. Not only that, oncologic safety could be threatened as some soft tissues, including lymph nodes, could be remained while in preserving the ALHA. There has been no standardized method to evaluate the ALHA, and to decide whether preserve or ligate it. This prospective study has been designed to develop the decision algorithm to define the ALHA preservation/ligation, using near-infrared fluorescence imaging during surgery. "
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
50
Entire fluorescence defect on the Lt. lobe of liver → Preservation of the aberrant left hepatic artery
Partial fluorecence defect on the Lt. lobe of liver → Ligation of the aberrant left hepatic artery
No fluorescence defect on the Lt. lobe of liver → Ligation of the aberrant left hepatic artery
GangnamSeverance Hospital
Seoul, South Korea
The safety and efficacy of the decision algorithm for the aberrant left hepatic artery preservation/ligation with real time near-infrared fluorescence imaging
Investigator discretionally designed the decision algorithm for aberrant left hepatic artery preservation/ligation with real time near-infrared fluorescence imaging. The order of the algorithm is as follows: First, when surgeons identify the aberrant left hepatic artery during surgery, clamping the artery and injectioning indocyanine green (5mg/mL) intravenously would be performed. After that, in a few seconds, liver perfusion could be detected through real time near-infrared fluorescence imaging. The ligation or preservation of the aberrant left hepatic artery would be decided according to the proportion of the near-infrared fluorescence imaging defect. Investigator's like to confirm the safety and efficacity of this decision algorithm.
Time frame: Real time near-infrared fluorescence image will be obtained during the surgery.
Number of participants with liver-related postoperative complications as assessed by serum aspartate transaminase(AST) and alanine transferase(ALT)
The elevated proprtion of the serum aspartate transaminase(AST, IU/L) and alanine transferase(ALT, IU/L) compared to preoperative value will be calculated and compared by groups.
Time frame: Serum aspartate transaminase(AST, IU/L) and alanine transferase(ALT, IU/L) will be estimated in postoperative 1st, 2nd, 3rd and 5th day.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.