The goal of this clinical trial is to compare different doses of AURN001 in patients with corneal edema secondary to corneal endothelial dysfunction. The main questions the clinical trial aims to answer are whether AURN001 effective and safe. Participants will receive a single injection of AURN001. A comparison between low, medium, and high doses of AURN001 against the contribution of each element, cells alone and Y27632 alone, will be conducted to determine the effects on corneal edema.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
QUADRUPLE
Enrollment
97
Corneal Endothelial Cells and Y27632
Corneal Endothelial Cells
Y27632
Aurion Biotech site
Little Rock, Arkansas, United States
Aurion Biotech site
Los Angeles, California, United States
Aurion Biotech site
San Francisco, California, United States
Aurion Biotech site
Atlanta, Georgia, United States
Aurion Biotech site
Indianapolis, Indiana, United States
Aurion Biotech site
Wichita, Kansas, United States
Aurion Biotech site
Minnetonka, Minnesota, United States
Aurion Biotech site
Garden City, New York, United States
Aurion Biotech site
Winston-Salem, North Carolina, United States
Aurion Biotech site
Cincinnati, Ohio, United States
...and 10 more locations
Percentage of Participants Achieving ≥15-letter Improvement in Best-corrected Visual Acuity (BCVA) at Month 6 - Imputed Data
Best-corrected visual acuity was assessed using Early Treatment Diabetic Retinopathy Study(ETDRS) method, standard for vision testing. Standardized Sloan letter charts with 5 letters per line, decreasing by 0.1 logarithm of minimum angle of resolution (LogMAR) per line, were used at 4 meters (or 1 meter if ≤19 letters were read, with +0.75 spherical power added). Each correct letter equaled one point (0.02 LogMAR), with 85 letters (0.0 LogMAR) corresponding to 20/20 Snellen, 70 letters (+0.3) to 20/40, and 35 letters (+1.0) to 20/200. A gain of ≥15 letters (0.3 LogMAR, 3 lines) was clinically meaningful. Data from the study eye only were included in the analysis. Participants read letters aloud, guessing encouraged, and all responses recorded for accuracy. Data presented represent number of participants with available BCVA measurements at Month 6, with those who had missing data, underwent rescue surgery before Month 6, or discontinued study prior to Month 6 imputed as non-responders.
Time frame: Month 6
Change From Baseline in BCVA at Month 6
Best-corrected visual acuity was assessed using the Early Treatment Diabetic Retinopathy Study (ETDRS) method, the standard for vision testing. Standardized Sloan letter charts with five letters per line, decreasing by 0.1 logarithm of the minimum angle of resolution (LogMAR) per line, were used at 4 meters (or 1 meter if ≤19 letters were read, with +0.75 spherical power added). Each correct letter equaled one point (0.02 LogMAR), with 85 letters (0.0 LogMAR) corresponding to 20/20 Snellen, 70 letters (+0.3) to 20/40, and 35 letters (+1.0) to 20/200. A gain of ≥15 letters (0.3 LogMAR, 3 lines) was clinically meaningful. Data from the study eye only were included in the analysis. Participants read letters aloud, guessing encouraged, and all responses recorded for accuracy. Baseline was defined as the last measurement prior to the study drug injection on Day 1. Change from baseline values was calculated as follow-up visit minus baseline visit.
Time frame: Baseline (Day 1) and at Month 6
Change From Baseline in Central Corneal Thickness (CCT) at Month 6
Central corneal thickness was measured by pachymetry which is an essential anatomical marker for detecting the presence or absence of edema and serves as a supportive indicator of treatment efficacy. Baseline was defined as the last measurement prior to the study drug injection on Day 1. Change from baseline values was calculated as follow-up visit minus baseline visit.
Time frame: Baseline (Day 1) and at Month 6
Percentage of Participants Achieving ≥15-letter Improvement in BCVA at All Timepoints - Observed Data
Best-corrected visual acuity was assessed using the Early Treatment Diabetic Retinopathy Study (ETDRS) method, the standard for vision testing. Standardized Sloan letter charts with five letters per line, decreasing by 0.1 logarithm of the minimum angle of resolution (LogMAR) per line, were used at 4 meters (or 1 meter if ≤19 letters were read, with +0.75 spherical power added). Each correct letter equaled one point (0.02 LogMAR), with 85 letters (0.0 LogMAR) corresponding to 20/20 Snellen, 70 letters (+0.3) to 20/40, and 35 letters (+1.0) to 20/200. A gain of ≥15 letters (0.3 LogMAR, 3 lines) was clinically meaningful. Data from the study eye only were included in the analysis. Participants read letters aloud, guessing encouraged, and all responses recorded for accuracy. The data presented reflect only participants with non-missing BCVA at each corresponding visit.
Time frame: At Week 4 and at Months 2, 3, 4.5, 6, 9 and 12
Change From Baseline in BCVA at All Other Timepoints
Best-corrected visual acuity was assessed using the Early Treatment Diabetic Retinopathy Study (ETDRS) method, the standard for vision testing. Standardized Sloan letter charts with five letters per line, decreasing by 0.1 logarithm of the minimum angle of resolution (LogMAR) per line, were used at 4 meters (or 1 meter if ≤19 letters were read, with +0.75 spherical power added). Each correct letter equaled one point (0.02 LogMAR), with 85 letters (0.0 LogMAR) corresponding to 20/20 Snellen, 70 letters (+0.3) to 20/40, and 35 letters (+1.0) to 20/200. A gain of ≥15 letters (0.3 LogMAR, 3 lines) was clinically meaningful. Data from the study eye only were included in the analysis. Participants read letters aloud, guessing encouraged, and all responses recorded for accuracy. Baseline was defined as the last measurement prior to the study drug injection on Day 1. Change from baseline values was calculated as follow-up visit minus baseline visit.
Time frame: Baseline (Day 1) and at Week 4, Months 2, 3, 4.5, 6, 9 and 12
Change From Baseline in CCT at All Other Timepoints
Central corneal thickness was measured by pachymetry which is an essential anatomical marker for detecting the presence or absence of edema and serves as a supportive indicator of treatment efficacy. Baseline was defined as the last measurement prior to the study drug injection on Day 1. Change from baseline values was calculated as follow-up visit minus baseline visit.
Time frame: Baseline (Day 1) and at Weeks 1 and 4, Months 2, 3, 4.5, 6, 9, and 12
Percentage of Participants Achieving ≥10-letter Improvement in BCVA at All Timepoints - Observed Data
Best-corrected visual acuity was assessed using the Early Treatment Diabetic Retinopathy Study (ETDRS) method, the standard for vision testing. Standardized Sloan letter charts with five letters per line, decreasing by 0.1 logarithm of the minimum angle of resolution (LogMAR) per line, were used at 4 meters (or 1 meter if ≤19 letters were read, with +0.75 spherical power added). Each correct letter equaled one point (0.02 LogMAR), with 85 letters (0.0 LogMAR) corresponding to 20/20 Snellen, 70 letters (+0.3) to 20/40, and 35 letters (+1.0) to 20/200. A gain of ≥15 letters (0.3 LogMAR, 3 lines) was clinically meaningful. Data from the study eye only were included in the analysis. Participants read letters aloud, guessing encouraged, and all responses recorded for accuracy. The data presented reflect only participants with non-missing BCVA at each corresponding visit.
Time frame: At Week 4 and at Months 2, 3, 4.5, 6, 9 and 12
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.