The goal of this prospective, randomized, open label, cross over study to assess the seal, comfort, usability, and performance of the prototype Oran Park mask system (referred to as Mask A in this study protocol) in the home environment. Comparisons will be made against Fisher \& Paykel's Evora Full mask system (referred to as Mask B in this study protocol, an FDA cleared benchmark mask) and the participant's own mask. Patients diagnosed with Obstructive Sleep Apnea and are current CPAP users on a tube down full-face mask system will be recruited to the study to evaluate the Oran Park mask system and the Evora Full mask system for up to 7 nights each, in the home environment, whilst using their own CPAP device. The overall purpose is to evaluate the performance of the prototype Oran Park mask system compared to an FDA cleared benchmark mask (Evora Full) in relation to seal, comfort, usability, ease of use, preference, AHI, and objective therapy data.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
58
Mask A (Oran Park Mask) for 7 days followed by Mask B (Evora Mask) for 7 days
Mask B (Evora Mask) for 7 days followed by Mask A (Oran Park Mask) for 7 days.
Sleep Data
San Diego, California, United States
Clayton Sleep Institute
St Louis, Missouri, United States
11 point Likert Scale Questionnaire
• Subjective scores will be collected from subjects on each attribute being assessed (e.g. seal, comfort, ease of use etc.). Scores will be collected using an 11-point Likert Scale Questionnaire. Minimum value will be zero. Maximum value will be 10. A higher score indicates better outcomes. A score of 10 is considered very favorable, and a score of 0 is very unfavorable.
Time frame: 7 days
Apnea Hypopnea Index (AHI)
• The AHI recorded by the subject's PAP device while using their own mask will be compared to the AHI recorded by the subject's PAP device while using the Oran Park mask and the Evora Mask. The AHI will be obtained from the ResMed AirView Compliance Reports downloaded from the subject's PAP device during the study visits.
Time frame: 7 days
Leak
The median air leak (L/minute) recorded by the subject's PAP device while using their own mask will be compared to the median air leak (L/minute) recorded by the subject's PAP device while using the Oran Park mask and the Evora mask. The median air leak will be obtained from the ResMed AirView Compliance Reports downloaded during the study visits.
Time frame: 7 days
Pressure Differences
The median air pressure (cmH2O) used during PAP therapy recorded by the subject's PAP device while using their own mask will be compared to the median air pressure (cmH2O) recorded by the subject's PAP device while using the Oran Park mask and the Evora mask. The median air pressure levels will be obtained from the ResMed AirView Compliance Reports downloaded from the subject's PAP device during the study visits.
Time frame: 7 days
Compliance
The subject's average daily hours of use of PAP therapy recorded by the subject's PAP device while using their own mask will be compared to the average daily hours of use recorded by the subject's PAP device while using the Oran Park mask and the Evora mask. The average daily hours of use will be obtained from the ResMed AirView Compliance Reports downloaded from the subject's PAP device during the study visits.
Time frame: 7 days