The aim of this crossover clinical study was the evaluation and comparison of masticatory performance and patient satisfaction for patients rehabilitated with conventional heat cured acrylic resin and 3D printed mandibular implant overdentures retained with bar attachment. it was concluded that 3D printed implant overdenture showed promising results regarding chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdenture.
The aim of this crossover clinical study was the evaluation and comparison of masticatory performance and patient satisfaction for patients rehabilitated with conventional heat cured acrylic resin and 3D printed mandibular implant overdentures retained with bar attachment. Materials and Methods: Twelve completely edentulous healthy participants received new conventional dentures. Four interforaminal implants were inserted in the mandible. After osseointegration, bar was constructed with trapezoidal configuration. Each patient received randomly the following overdentures using a crossover design: conventional heat cured acrylic resin overdenture, 3d printed overdenture ( developed by scanning of mandibular conventional overdenture). Masticatory performance was evaluated with the two-colour mixing ability test after 5, 10, 20, 30, and 50 masticatory cycles. Patient satisfaction was also measured using McGill Denture Satisfaction Questionnaire. Evaluation was done after 3 months of using each overdenture. Conclusion: Within this clinical study limitations, 3D printed implant overdenture showed promising results regarding chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdenture.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
16
Procedure/ surgery: Surgical placement of dental implants, four interforaminal dental implants were placed
Device: attachment, implants were connected to each others by 3 implant assembly in a trapezoidal design implants were loaded after 3 months of osseo-integration Control Group: patients received coventionally constructed heat cured overdenture Study Group: patients received 3d printed overdenture
Mansoura University, Faculty of dentistry
Al Mansurah, Egypt
Chewing efficiency
Chewing efficiency was assessed using the previously documented two-color mixing ability test (colorimetric method) as follow: Two samples were prepared from two colored chewing gums. Patients were asked to keep the gum sample intraorally for one minute then start to chew it for 5, 10, 20, 30 and 50 strokes respectively. Five samples were used for the tests, the samples were spat into clear plastic bags. All samples were evaluated after flattening to wafers of 1 mm thickness. scanned by Digital scanner from both sides stored in Adobe Photoshop® format (psd). Then the color range tool and histogram function were used to pick out the unmixed white parts of the image. Then the ratio of Unmixed Fraction (UF) was computed using the following formula: (Pixels white side a + Pixels white side b) - 2× Pixels of scale / 2 × Pixels all. As a reference scale, a scanned piece of unmixed gum was copied in each image
Time frame: at time of insertion of prosthesis T(0), 3 months after insertion T(3).
Patient satisfaction
The eight core of McGill Denture Satisfaction Questionnaire (MDSQ) items were used to record patient satisfaction with their mandibular complete removable denture. One question concerns overall satisfaction with existing prostheses, whereas the other seven questions refer to specific aspects that may influence overall satisfaction: ease of cleaning; ability to speak; comfort; aesthetics/appearance; and denture stability; chewing ability; chewing function. Respondents provided answers on a 100-mm visual analogue scale. Patients were encouraged to respond to the survey questionnaire after functioning with each type of denture for 3-months.
Time frame: at time of insertion of prosthesis T(0), 3 months after insertion T(3).
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.