The objective of this observational study is to evaluate the primary stability of dental implants and the relationship between insertion torque and patients' pain levels assessed with the visual analogue scale (VAS)
Primary implant stability plays a key role in providing osseointegration. Higher insertion torque indicates higher primary stability. However, the effect of increased insertion torque on patient pain levels has not been clearly demonstrated. Several methods for measuring primary stability have been defined so far. Insertion torque, periotest measurements, and resonance frequency analysis are mostly preferred due to their ease of use and non-invasiveness. The aim of the present study is to evaluate the relationship between insertion torque and patients' pain levels assessed with the visual analogue scale (VAS) and to assess the relationship between insertion torque, periotest measurements, and resonance frequency analysis.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
15
Fifteen patients with bilateral single-tooth loss in the posterior mandible will be included in the study. One implant was randomly placed with high insertion torque in each patient. A total of 15 implants will be placed, and insertion torque values will be recorded.
Fifteen patients with bilateral single-tooth loss in the posterior mandible will be included in the study. One implant was randomly placed with low insertion torque in each patient. A total of 15 implants will be placed, and insertion torque values will be recorded.
Pain levels assessed with the visual analogue scale (VAS)
Patients will be asked to record the number of painkillers taken each day and evaluate their pain levels using a 0-10 VAS form before and after the operation. A score of 0 indicated no pain while 10 indicated the worst pain possible. A VAS score of 1-3 indicated mild pain, 4-6 indicated moderate pain, and 7-10 indicated very severe pain.
Time frame: 7 days
Insertion torque values
After the implant slots were prepared, the coronal part of the implants (MIS Implant Technologies, Bar Lev Industrial Park, Israel) were placed into the slots at 25 rpm without irrigation until the coronal part was at the same level with the ridge top. The maximum insertion torque was recorded while the implants were placed with the help of a physiodispenser that can measure the insertion torque (Kavo Expertsurg lux physiodispenser, KaVo Dental GmbH, Biberach, Germany).
Time frame: 1 day
Periotest measurements
Measurements were made with the Periotest (Siemens AG, Bensheim, Germany) device and recorded as PTV (perio test value).
Time frame: 1 day
Resonance frequency analysis values
A SmartPeg (Integration Diagnostics AB; Gothenburg, Sweden) suitable for the implant was attached to measure primary implant stability with radiofrequency. Radiofrequency analysis was performed in both mesiodistal and buccolingual directions with the Osstell Mentor (Integration Diagnostics AB; Gothenburg, Sweden) device and the measurements were recorded.
Time frame: 1 day