This study aims to evaluate the changes in the stability and bone-implant contact surface of implants of the same macro-design placed with particle grafting in the fresh extraction socket, without grafting, and placed in healed implant sites.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
30
Dental implant placement
Marmara University School of Dentistry
Istanbul, Turkey (Türkiye)
Change in Implant Stability Quotient (ISQ) values
Implant Stability Quotient (ISQ) is a scale from 1 to 100, to quantify implant stability in bone (higher values mean higher stability). ISQ numerical values are generated by applying resonance frequency analysis (RFA) or sound waves through a specialized peg attached to the implant. Data were combined to reduce the number of intervals for analysis purposes. Data from intervals were combined as follows: T0: baseline T1: follow-up of eight weeks T2: follow-up of twelve weeks
Time frame: 12 weeks
Change in bone-implant contact surface
The tooth slated for extraction will be segmented from the preoperative CBCT data, followed by a virtual tooth extraction process. For each patient, intraoral surface scanning with the scanbodies in place will be conducted using an intraoral scanner. This datas will be overlaid onto the postoperative intraoral scan image. The area where the implant surface made contact with the extracted tooth surface will be identified as the surface without implant bone contact (BINC), while the remaining area will be designated the bone implant contact (BIC) surface. By subtracting the sum of the BINC and BIC from the entire implant surface, the implant surface facing the gap space (IGS) and its corresponding area on the BINC side will obtain. To isolate the BIC surface for measurement, the sum of the BINC and BIC from the sum of the BINC and IGS will subtracted. This result will then be added to the total implant surface measurement, divided by two, allowing for the measurement of the BIC surface.
Time frame: 12 weeks
Primary insertion torque value
The torque value was recorded as insertion torque value of this case at the moment when the implant positioned at the 1mm under the socket wall edge and correct hex position. It gives numerical values from 0 to 100 (higher values mean higher stability).
Time frame: 1 day At the implant placement
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.