This is a prospective safety and feasibility study to evaluate the safety of the FieldForce™ Ablation system in patients with ventricular arrhythmia divided into two groups: VT (VCAS-I) and frequent premature ventricular complex (VCAS-II).
Summary: Ventricular arrythmias are common but often undertreated. The most effective pharmacologic management and implantable devices are used to treat deadly arrythmias like ventricular tachycardia (VT) and ventricular fibrillation (VF). However, the efficacy of antiarrhythmic drugs (AADs) has been proven to be low, and implantable cardioverter defibrillators (ICDs) treat VT but do not prevent it. Prospective trials demonstrate that VT ablation is by far the most effective therapy for ventricular tachycardia and in some cases it is curative. Despite overwhelming evidence that catheter ablation is superior, there are many technical barriers that prevent widespread application of this therapy. Furthermore, non-fatal ventricular arrythmias such as premature ventricular contractions (PVCs) are treatable by catheter ablation. The technical challenges facing VT and PVC ablations are similar as current technologies are optimized to treat atrial arrythmias often at the expense of performance in the ventricle. Pulsed field ablation (PFA) is a new ablation method for the therapy of arrhythmias. PFA is considered as a non-thermal and low-energy method of ablation. This technique is characterized by pulse trains of short-duration and high-voltage electrical impulses that result in electric field-mediated tissue injury. The very strong electric fields put strain on cellular compartmentalization. These changes can be reversible, and cells can recover with no consequences; however, if compartmentalization is disrupted for an extended period of time, it results in metabolic injury and cell death. This mechanism is also known as electroporation. Different cell types are sensitive to these types of insults leading to tissue selectivity in the heart. Clinical studies have already demonstrated the feasibility and safety of PFA for the treatment of atrial fibrillation. However, there is less data on the application of PFA for VT. Therefore, this Pre-Market, First-In-Human, Pilot, Interventional, Clinical Investigation aims to evaluate Safety and Feasibility of the FieldForce™ Ablation system in patients with ventricular tachycardia divided into two groups: ventricular tachycardia (VCAS-I) and unifocal premature ventricular complex (VCAS-II).
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
60
Catheter ablation is a minimally invasive procedure. The physician advances multiple catheters into the heart that are used to diagnose and localize abnormal cardiac tissue involved in the initiation and maintenance of ventricular tachycardia and/or PVCs. Once the abnormal tissue is identified a specialized catheter is advanced to the target and energy is applied to destroy the abnormal tissue. The intervention will be identical to the conventional procedure except that an investigational ablation catheter will be used to deliver energy.
Catheter ablation is a minimally invasive procedure. The physician advances multiple catheters into the heart that are used to diagnose and localize abnormal cardiac tissue involved in the initiation and maintenance of ventricular tachycardia and/or PVCs. Once the abnormal tissue is identified a specialized catheter is advanced to the target and energy is applied to destroy the abnormal tissue. The intervention will be identical to the conventional procedure except that an investigational ablation catheter will be used to deliver energy.
Na Homolce Hospital
Prague, Czechia
RECRUITINGIKEM
Prague, Czechia
RECRUITINGSafety Endpoint Acute
device-related or procedure-related Serious Adverse Events
Time frame: < 30 days
Reduction in clinical arrhythmia burden (VCAS-I)
Compare the baseline arrhythmia logs recorded on the ICD to post procedure arrhythmia logs
Time frame: baseline, 90 days & 180 days
Reduction in clinical arrhythmia burden (VCAS-II)
Compare the baseline 24-hour Holter PVC burden after ablation
Time frame: baseline, after 90 days and no longer than 120 days
Procedure duration (average minutes of procedure time)
Time points in the procedure will be recorded and stratified by group
Time frame: 1 day
Evaluate VT inducibility (VCAS-I) pre and post ablation
VT inducibility using programed stimulation using two drive cycle lengths and triple extra stimuli will be performed.
Time frame: index procedure
Detect Ischemic scar homogenization (VCAS-I)
Ischemic scar homogenization using cardiac magnetic resonance (CMR) will be performed before ablation at baseline and 90 days.
Time frame: baseline and 90 days