In our study, changes in vastus lateralis muscle oxygenation will be evaluated with the Moxy device, a functional infrared oxygen measurement device, during the inspiratory muscle fatigue protocol in COPD cases and the healthy control group.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
30
It will be performed using a powerbreath device at 60% of the maximum inspiratory pressure (MIP) amount obtained by measuring mouth pressure. The protocol includes 7 sets consisting of 2 minutes of inspiratory effort and 1 minute of rest. To further confirm the occurrence of fatigue, the patient will score fatigue using the modified Borg scale, and the score will be 5 or above11. During the application, heart rate, blood pressure and peripheral oxygen saturation will be monitored. The measurement will be performed once for each case.
Yedikule Chest Disease Hospital
Istanbul, Zeytinburnu, Turkey (Türkiye)
RECRUITINGLower extremity muscle oxygenation level measurement
Near Infrared Reflection Spectroscopy device will be used. The device measures and monitors muscle oxygen by taking the reflected rays of infrared rays given to the body from two different sensors to measure muscle oxygenation levels in muscle tissue. The measurement will be made in the dominant lower extremity, and the device will be placed in the mid-thigh region at the distance between the spina iliaca anterior superior reference point and the midpoint of the patella.
Time frame: 20 minutes
Lower extremity muscle total hemoglobin amount level measurement
Near Infrared Reflection Spectroscopy device will be used. The device measures and monitors muscle total hemoglobin amount by taking the reflected rays of infrared rays given to the body from two different sensors to measure muscle oxygenation levels in muscle tissue. The measurement will be made in the dominant lower extremity, and the device will be placed in the mid-thigh region at the distance between the spina iliaca anterior superior reference point and the midpoint of the patella.
Time frame: 20 minutes
Peripheral oxygen saturation measurement
During the fatigue protocol, it will be measured with a finger pulse oximeter attached to the finger
Time frame: 20 minutes
Forced vital capacity (FVC),
Pulmonary function test will perform by using the Pony Fx spirometry device, and according to the American Thoracic Society (ATS) guidelines. FVC is the volume of air that can forcibly be blown out after full inspiration.
Time frame: 5 minutes
Respiratory muscle strength
The mouth pressure measurement (maximum inspiratory and expiratory pressure) will perform with the Pony Fx spirometry device. Patient will place a rubber mouthpiece with flanges, on the device, exhale/inhale slowly and completely, and then will try to breath in as hard as possible. The patient will allow to rest for about a minute and the maneuver will repeat. The aim is that the variability between measurements is less than 10 cm H2O. The maximum value will obtain.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 10 minutes
Forced expiratory volum in one second (FEV1)
Pulmonary function test will perform by using the Pony Fx spirometry device, and according to the American Thoracic Society (ATS) guidelines. FEV1 is the volume of air that can forcibly be blown out in first 1-second, after full inspiration
Time frame: 5 minutes