The aim of the study is to assess which prophylaxis methods is the most suitable for peri-implant hygiene between erythritol and ultrasonic scaler with peek inserts. A randomized clinical trial will be conducted on the patient. Patients will be randomly divided into two groups: * Erythritol group: erythritol with a particle size of \~14 µm will be used for 5 seconds (AIRFLOW® PLUS EMS) * Ultrasonic scaler group: a piezoelectric handpiece with peek inserts (Mini Piezon EMS; PI EMS) will be used. Different subgroups will be defined according to the material of the dental crown of the related implant. The oral hygiene session will be carried out every 6 months (2-years follow-up; 6 sessions), after instruction and motivation of the patient, completion of the clinical chart with the recording of the Probing Depth (evaluation in mm of the peri-implant sulcus taken by a periodontal probe; 4 surfaces of the gingival margin are detected: vestibular, palatal/lingual, mesial, distal), Bleeding on Probing and Plaque Index.
The aim of the study is to assess which prophylaxis methods is the most suitable for peri-implant hygiene between erythritol and ultrasonic scaler with peek inserts. A randomized clinical trial will be conducted on the patient. Patients will be randomly divided into two groups: * Erythritol group: erythritol with a particle size of \~14 µm will be used for 5 seconds (AIRFLOW® PLUS EMS) * Ultrasonic scaler group: a piezoelectric handpiece with peek inserts (Mini Piezon EMS; PI EMS) will be used. Different subgroups will be defined according to the material of the dental crown of the related implant: feldspathic ceramic, zirconia and lithium disilicate. The oral hygiene session will be carried out every 6 months (2-years follow-up; 6 sessions), after instruction and motivation of the patient, completion of the clinical chart with the recording of the Probing Depth (evaluation in mm of the peri-implant sulcus taken by a periodontal probe; 4 surfaces of the gingival margin are detected: vestibular, palatal/lingual, mesial, distal), Bleeding on Probing and Plaque Index.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
120
erythritol with particle size of \~14 µm will be used for 5 seconds (AIRFLOW® PLUS EMS)
ultrasonic scaler, a piezoelectric handpiece with peek inserts (Mini Piezon EMS; PI, EMS) will be used.
Unit of Dental Hygiene - Section of Dentistry - Department of Clinical, Surgical, Diagnostic and Paediatrics - University of Pavia
Pavia, Lombardy, Italy
Change in Probing Depth (PD)
Evaluation in mm of the peri-implant sulcus taken by a periodontal probe. 4 surfaces of the gingival margin are detected: vestibular, palatal/lingual, mesial, distal.
Time frame: Baseline (T0), 6 months (T1), 12 months (T2), 18 months (T3) 24 months (T4)
Change in Bleeding on Probing (BoP)
Evaluation of the presence or absence of gingival bleeding during a probing with a dichotomous scoring (yes/no) of bleeding sites. The sum of the bleeding sites is divided for the total sites and multiplied per 100.
Time frame: Baseline (T0), 6 months (T1), 12 months (T2), 18 months (T3) 24 months (T4)
Change in Plaque Control Record
% assessment of the amount of plaque on dental surfaces; it is detected on 4 surfaces: distal, mesial, vestibular, lingual / palatal. The number of sites with plaque is divided by the total number of sites available in the mouth and multiplied by 100. Results indicate the index as a percentage.
Time frame: Baseline (T0), 6 months (T1), 12 months (T2), 18 months (T3) 24 months (T4)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.